[C46] Pressure roller thermistor being abnormal after the copier has become ready<br />

1. Check the pressure roller thermistor.<br />

(1) Check if the connector is not disconnected.<br />

(2) Check if the pressure roller thirmistor closely touches the surface of the pressure roller.<br />

(3) Check if the harness of the pressure roller thermistor is not open-circuited.<br />

2. Check the LGC board.<br />

(1) Check if the connector J334 is not disconnected.<br />

(2) Check if the conductor pattern on the LGC board is not short- or open-circuited.<br />

(3) Replace the LGC board.<br />

3. Clear the status counter.<br />

Change the current status counter value (08-400) “3” or “8” to “0”.<br />

<strong>AR</strong>-<strong>651</strong>/<strong>810</strong> <strong>TROUBLE</strong> SHOOTING 5 - 64