SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros
SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros
SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
[EB6] Paper left on the transport path<br />
Open the bypass unit cover. Is there any paper in front of the registration sensor?<br />
NO<br />
YES<br />
Remove the paper.<br />
Is the registration sensor working?<br />
(Perform the input check in the test mode: 03-[ENERGY SAVER]ON/[4]/[E)<br />
YES<br />
NO<br />
1. Check if the connector of the registration sensor is disconnected.<br />
2. Check if the connector J341 on the LGC board is disconnected.<br />
3. Check if the connector pins are disconnected and the harnesses are open-circuited.<br />
4. Check if the conductor pattern on the LGC board is short- or open-circuited.<br />
5. Replace the registration sensor.<br />
6. Replace the LGC board.<br />
Check the rollers. Replace them if they are worn out.<br />
5 - 13 <strong>AR</strong>-<strong>651</strong>/<strong>810</strong> <strong>TROUBLE</strong> SHOOTING