SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros
SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros
SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
[Procedure 2]<br />
Is the switch actuator for the front door working properly?<br />
YES<br />
NO<br />
Fix the mechanism.<br />
Is the front cover switch (MS2S) working normally?<br />
YES<br />
NO<br />
Replace the switch.<br />
Measure the voltage of J11-12 on the saddle switcher controller PC board when the front door is<br />
opened. Is it 5V?<br />
YES<br />
NO<br />
The front door opening/closing sensor is broken. Replace it.<br />
Replace the saddle stitcher controller PC board.<br />
[Procedure 3]<br />
Is the switch actuator for the delivery door working properly?<br />
YES<br />
NO<br />
Fix the mechanism.<br />
Is the delivery cover switch working normally?<br />
YES<br />
NO<br />
Replace the switch.<br />
Measure the voltage of J11-9 on the saddle stitcher controller PC board when the delivery door is<br />
opened. Is it 5V ?<br />
YES<br />
NO<br />
The delivery cover sensor (PI3S) is broken. Replace it.<br />
Replace the saddle stitcher controller PC board.<br />
<strong>AR</strong>-<strong>651</strong>/<strong>810</strong> <strong>TROUBLE</strong> SHOOTING 5 - 94