[Procedure 2]<br />

Is the switch actuator for the front door working properly?<br />

YES<br />

NO<br />

Fix the mechanism.<br />

Is the front cover switch (MS2S) working normally?<br />

YES<br />

NO<br />

Replace the switch.<br />

Measure the voltage of J11-12 on the saddle switcher controller PC board when the front door is<br />

opened. Is it 5V?<br />

YES<br />

NO<br />

The front door opening/closing sensor is broken. Replace it.<br />

Replace the saddle stitcher controller PC board.<br />

[Procedure 3]<br />

Is the switch actuator for the delivery door working properly?<br />

YES<br />

NO<br />

Fix the mechanism.<br />

Is the delivery cover switch working normally?<br />

YES<br />

NO<br />

Replace the switch.<br />

Measure the voltage of J11-9 on the saddle stitcher controller PC board when the delivery door is<br />

opened. Is it 5V ?<br />

YES<br />

NO<br />

The delivery cover sensor (PI3S) is broken. Replace it.<br />

Replace the saddle stitcher controller PC board.<br />