[F07] Communication error between SYS board and LGC board<br />

[F11] Communication error between SYS board and SLG board<br />

(1) Check if the connectors J114 and J105 on the SYS board are disconnected.<br />

(2) Check if the connector J4 on the SLG board is disconnected.<br />

(3) Check if the harness connecting the SYS and SLG boards is open-circuited and the connector pins<br />

are disconnected.<br />

(4) Check if the harness connecting the SYS board and LGC board is open-circuited and the connector<br />

pins are disconnected.<br />

(5) Check the version of the FROM on the SYS board.<br />

(6) Check the version of the MROM on the LGC board.<br />

(7) Check the version of the SROM on the SLG board.<br />

(8) Replace the SYS board.<br />

(9) Replace the SLG board.<br />

(10) Replace the LGC board.<br />