[C58] Communication error between the IPC board and finisher<br />

Is a specified finisher used?<br />

YES<br />

Replace to the specified finisher.<br />

Is the harness between the IPC board and finisher control board open-circuited?<br />

NO<br />

Replace the harness.<br />

Is the conductor pattern on the IPC board is short- or open-circuited?<br />

NO<br />

Replace the IPC board.<br />

Replace the finisher control board.<br />

[C59] Communication error between the main CPU and laser CPU<br />

(1) Check if the harness between the LGC board and PLG board is not disconnected or open-circuited.<br />

(2) Check if the conductor pannern around IC13, IC25, IC57, J327 and J342 on the LGC board is not<br />

short- or open-circuited.<br />

(3) Check if the conductor pattern around IC4, IC19 and J202 on the PLG board is not short- or open-<br />

circuited.<br />

NO<br />

YES<br />

YES<br />

(4) Replace the LGC board.<br />

(5) Replace the PLG board.<br />

5 - 69 <strong>AR</strong>-<strong>651</strong>/<strong>810</strong> <strong>TROUBLE</strong> SHOOTING