SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros
SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros
SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
[EA9] Saddle stitcher door opened during printing<br />
Is there any paper remaining on the transport path in the finisher, saddle stitcher section or main unit?<br />
NO<br />
YES<br />
Remove the paper.<br />
Is the saddle stitcher door closed?<br />
YES<br />
NO<br />
Close the door.<br />
Is either of the connectors J10 or J11 on saddle stitcher controller PC board disconnected?<br />
Are the harnesses connecting the saddle stitcher controller PC board and cover opening sensors<br />
(PI2S: front door opening/closing sensor, PI3S: delivery cover sensor, PI19S: inlet cover sensor)<br />
open-circuited?<br />
NO<br />
YES<br />
Connect the connector securely. Replace the harness.<br />
Are the cover opening sensors working properly?<br />
YES<br />
NO<br />
1. Connect the connectors of the cover opening sensors securely.<br />
2. Replace the cover opening sensors.<br />
Replace the finisher controller PC board.<br />
5 - 45 <strong>AR</strong>-<strong>651</strong>/<strong>810</strong> <strong>TROUBLE</strong> SHOOTING