5.6 Start-up<br />

WARNING<br />

Do not operate the iH system with any enclosure panels removed and do not<br />

touch any parts of the pump(s) when the iH system is on. Surfaces of the<br />

pump(s) are very hot and can cause injury to people.<br />

WARNING<br />

Ensure that it is safe to start the iH system. If you do not (and, for example,<br />

maintenance is being performed on components downstream of the iH<br />

system), you could cause injury to people.<br />

Notes:<br />

When you use the Pump Display Terminal to start up the iH system, we recommendthat you do<br />

not disconnect the Terminal from the iH system; if you do, you will not be able to use the Terminal<br />

to instantly shut down the iH system: see Section 5.5.<br />

Operation of the iH system with high inlet pressure may result in shaft-seal pressure warnings<br />

(refer to Table 6-1): the operation of the iH system will not be affected, and you can ignore these<br />

warnings.<br />

Use the following procedure to start up the iH system:<br />

1. Switch on the cooling-water supply, the nitrogen supply and the external electrical supply<br />

(if not already on).<br />

2. Ensure that the exhaust-extraction system is not blocked and that valves in the<br />

exhaust-extraction system are open.<br />

3. Ensure that the Pump Display Terminal has control of the iH system: refer to Section 5.5.<br />

4. Refer to Figure 4-1. Look at the display (2) on the Pump Display Terminal:<br />

• If there are any warnings or alarms, take the necessary corrective action (refer to Section 6);<br />

do not start the iH system.<br />

• If there are no alarms or warnings displayed, use the Switch On menu to switch on the iH<br />

system.<br />

When you switch on, the following actions will occur (with a small time delay between each<br />

action):<br />

• The LED on the On button on the Pump Display Terminal will start to flash.<br />

• The HCDP pump will be switched on.<br />

• The LED on the On button on the Pump Display Terminal will stay permanently on.<br />

5-6 iH Dry Pumping Systems