Warning message Advisory message Meaning/recommended action<br />

WARNING 101 (a) there is a fault in the Control SMA, or<br />

(b) the emergency stop button has been<br />

pressed to shut down the iH system, or<br />

(c) there has been a transient electrical supply<br />

failure (longer than the hold-up time of the iH<br />

power supply).<br />

WARNING 113 There is a fault in the ADC (analogue-to-digital<br />

convertor) in the Control SMA; the Control<br />

SMA must be replaced.<br />

WARNING 209 SEE MANUAL The electrical supply voltage is too low. Check<br />

the electrical supply and the connections to the<br />

iH system and rectify as necessary.<br />

WARNING 211 SEE MANUAL The electrical supply voltage is too high.<br />

Check the electrical supply and the<br />

connections to the iH system and rectify as<br />

necessary.<br />

WARNING 309<br />

DP CURRENT LOW<br />

WARNING 311<br />

DP CURRENT HIGH<br />

WARNING 409<br />

DP POWER LOW<br />

WARNING 411<br />

DP POWER HIGH<br />

WARNING 412<br />

DP POWER HIGH<br />

OPEN CIRCUIT<br />

CHECK CONNECTION<br />

LEAK/DEBRIS<br />

SERVICE PUMP<br />

OPEN CIRCUIT<br />

CHECK CONNECTION<br />

LEAK/DEBRIS<br />

SERVICE PUMP<br />

LEAK/DEBRIS<br />

SERVICE PUMP<br />

The electrical current drawn by the HCDP<br />

pump is less than normal. Check that the<br />

electrical connections are correct and rectify as<br />

necessary. If the electrical connections are<br />

correct, a fuse in the Electrics Box may have<br />

failed.<br />

The electrical current drawn by the HCDP<br />

pump is higher than normal. There may be a<br />

leak in the system or process debris in the<br />

pump, or the pump motor may have failed.<br />

Inspect the pipelines and service the pump.<br />

The electrical power consumption of the<br />

HCDP pump is less than normal. Check that<br />

the electrical connections are correct and<br />

rectify as necessary. If the electrical<br />

connections are correct, a fuse in the Electrics<br />

Box may have failed.<br />

The electrical power consumption of the<br />

HCDP pump is higher than normal. There<br />

may be a leak in the system or process debris<br />

in the pump, or the pump motor may have<br />

failed. Inspect the pipelines and service the<br />

pump.<br />

Refer to the recommended actions for error<br />

number 411 in this table.<br />

Table 6-1 - Warning messages<br />

iH Dry Pumping Systems 6-21