6.18.1 Introduction<br />

Perform the following checks when you maintain your pumping system:<br />

• Check that the disconnect box is securely fitted on the wall.<br />

• Check that all electrical connections are secure and that electrical cables are not damaged.<br />

The disconnect box and photohelic switch/gauge contains no serviceable parts. Repair of<br />

faults by the user is limited to replacement of fuses, and resetting of the circuit breakers.<br />

If any other repairs are required, contact your supplier or your nearest BOC <strong>Edwards</strong> Service<br />

Centre for advice.<br />

6.18.2Fault finding<br />

If you suspect that a fault exists in the disconnect box, check the possible causes and carry out<br />

the remedial actions described in the following table before returning the disconnect box to a<br />

Service Centre.<br />

Symptom Probable Cause Recommendations<br />

The disconnect box will<br />

not power up<br />

A fuse has blown<br />

Check fuses F1 through F6<br />

and replace if required<br />

Incoming electrical supply has<br />

failed<br />

Check the electrical supply<br />

Photohelic gauge in warning state<br />

Rectify situation and reset CB1<br />

Brownout condition over 3 seconds Rectify situation and restart<br />

system<br />

Photohelic gauge will<br />

not operate<br />

Circuit breaker CB1 tripped<br />

Rectify situation and reset CB1<br />

6.18.3 Fuse replacement<br />

The fuses are mounted in standard fuse holders. The use of a fuse puller is recommended<br />

when checking or replacing blown fuses.<br />

If fuses blow regularly, this indicates a probable fault in the disconnect box or electrical<br />

connections. Isolate and rectify the fault before reusing the disconnect box.<br />

6-20 iH Dry Pumping Systems