2.4 Cooling-water supply<br />

Notes.<br />

Use treated water or non-corrosive industrial water to cool the iH system.<br />

Maximum supply pressure<br />

100 psig (6.9 bar, 6.9 x 10 5 Pa)<br />

Typical pressure differential<br />

across supply and return *<br />

iH80<br />

15 psi (1.03 bar, 1.03 x 10 5 Pa)<br />

iH600/iH1000<br />

15 psi (1.03 bar, 1.03 x 10 5 Pa)<br />

Minimum flow rate required for<br />

reliable iH system operation<br />

iH80 2 l.min -1<br />

iH600/iH1000 4 l.min -1<br />

Typical heat removed from iH system<br />

iH80<br />

2.5 kW<br />

iH600<br />

3.2 kW<br />

iH1000<br />

3.2 kW<br />

Maximum particle size in supply 0.03 mm 2<br />

Water supply quality<br />

Acidity 6.5 to 8.0<br />

Hardness<br />

< 100 p.p.m<br />

Resistivity > 1 k.cm -1<br />

Solids (turbidity)< 100 p.p.m<br />

* With cooling-water supply temperature of 20 o C and flow rate of 3 l.min -1 .<br />