APPENDIX B: Standards conformity<br />

The <strong>NewTom</strong> <strong>VG</strong>i equipment has been built in conformity with IEC normative regarding safety of electricmedical<br />

devices of similar typology and, particularly, with the normative:<br />

• IEC 60601-1: 1988-12 Medical electrical equipment - Part 1: General requirements for safety<br />

• IEC 60601-1-1: Edition 2.0 2000-12 Medical electrical equipment - Part 1-1: General requirements for<br />

safety - Collateral standard: Safety requirements for medical electrical systems<br />

• IEC 60601-1-2: 2001-09 Medical electrical equipment - Part 1-2: General requirements for safety -<br />

Collateral standard: Electromagnetic compatibility - Requirements and tests<br />

• IEC 60601-1-3:1994-07 Part 1: General requirements for safety - 3. Collateral standard: General<br />

requirements for radiation protection in diagnostic X-ray equipment<br />

• IEC 601-1-4: Edition 1.1 2000-04 Medical electrical equipment - Part 1-4: General requirements for safety -<br />

Collateral Standard: Programmable electrical medical systems<br />

• IEC 601-2-7: Edition 2 1998-02 Medical electrical equipment - Part 2-7: Particular requirements for the<br />

safety of high-voltage generators of diagnostic X-ray generators<br />

• IEC 601-2-28: Edition 1.0 1993-03 Medical electrical equipment - Part 2: Particular requirements for the<br />

safety of X-ray source assemblies and X-ray tube assemblies for medical diagnosis<br />

• IEC 601-2-32: Edition 1.0 1994-03 Medical electrical equipment - Part 2: Particular requirements for the<br />

safety of associated equipment of X-ray equipment<br />

• IEC 601-2-44: Edition 2.1, 2002-11 Medical Electrical Equipment - Part 2.44:Particular requirements for the<br />

safety of X-ray equipment for computed tomography<br />

• IEC 60825-1: 2003-02 Edition 4, Safety of laser products - Part 1: Equipment classification, requirements<br />

and user's guide<br />

• 21 CFR 1020.33 Computed tomography (CT) equipment April 1, 2006]<br />

CLASSIFICATION IEC 601-1<br />

Protection against electrical shock<br />

Degree of protection against electric shock<br />

Use with flammable anesthetics<br />

CLASS I<br />

TYPE B<br />

Have not been evaluated for use in the<br />

presence of a flammable anaesthetic mixture<br />

with air, oxygen, or nitrous oxide.<br />

Sterilization and disinfection methods<br />

The device is supplied not sterile and it must<br />

not be subjected to sterilization.<br />

See chapter 3.5 “Cleaning and disinfection”<br />

Mode of operation<br />

Continuous with intermittent loading.<br />

Duty cycle<br />

18sec ON / 15 min. OFF<br />

modalities<br />

Full and Zoom<br />

27sec ON / 15 min. OFF HiRes Zoom modality<br />

Rev. 1.0 - 02/15/2009 Page 64 of 72