C H A P T E R 5<br />

<strong>Intel®</strong> NetStructure <strong>6000</strong> <strong>Switch</strong> User Guide<br />

gated>config<br />

gated#set routerid 193.21.2.2<br />

gated#add ospf<br />

gated#ospf<br />

gated/ospf#add area[0.0.0.2]<br />

gated/ospf#area[0.0.0.2]<br />

gated/ospf/area[0.0.0.2]#add if[193.21.2.22]<br />

gated/ospf/area[0.0.0.2]#activate<br />

gated/ospf/area[0.0.0.2]#save<br />

Creating Virtual Links<br />

The OSPF protocol requires that all areas must be connected to the<br />

backbone. OSPF requires that every area connect to the backbone and<br />

that every area, including the backbone area, be contiguous.<br />

A virtual link is used to logically connect an area to the backbone,<br />

when it cannot physically connect to the backbone. The two end<br />

points of a virtual link are Area Border Routers (ABR). The virtual<br />

link must be configured for each ABR.<br />

To configure a virtual link<br />

• Add the area for each Area Board Router.<br />

• Add the Router ID of the Area Border Router connected to each<br />

area.<br />

• Add the backbone.<br />

• Set the transit area used to link the virtual link to the backbone.<br />

In the Virtual Link Topology example, Area 0.0.0.1 is connected to<br />

the backbone through ABR1. Area 0.0.0.2 needs to be connected<br />

through ABR1 to Area 0.0.0.1 to be connected to the backbone.<br />