C H A P T E R 1<br />

Using the <strong>Switch</strong><br />

• Trigger: temperature sensor has reached 48º C<br />

Critical Warning: The switch temperature has reached 47º C.<br />

Automatic shutdown has commenced.<br />

In Intel Device View, this is a red warning alert.<br />

• Trigger: temperature sensor has reached 44, 46 or 47º C and then<br />

has dropped back to 43º C.<br />

Critical Warning: The switch temperature has dropped below<br />

critical limits. The temperature is now 43º C.<br />

In Intel Device View, this is a green alert.<br />

When one or two fans have failed, the warning messages are:<br />

• Trigger: temperature sensor has reached 38º C<br />

Critical Warning: The switch has reached 38C. Automatic<br />

shutdown will occur at 40º C.<br />

In Intel Device View, this is a red warning alert. This message is sent<br />

every minute until the temperature drops below 38º C.<br />

• Trigger: temperature sensor has reached 39º C<br />

Critical Warning: The switch has reached 39ºC. Automatic<br />

shutdown will occur at 40º C.<br />

In Intel Device View, this is a red warning alert. This message is sent<br />

every minute until the temperature drops below 38º C.<br />

To replace the fan assembly<br />

Warning Only fan assembly modules identified as “Hot Swappable<br />

Fan” on the front of the chassis can be replaced<br />

without powering down the switch.<br />

1 Locate the fan assembly on the front panel of the chassis.<br />

2 Unscrew the capture panel screws on the fan assembly panel.<br />

3 Grasp the fan assembly with both hands and carefully pull it out<br />

from the backplane.<br />