C H A P T E R 1<br />

Using the <strong>Switch</strong><br />

Power Supply Replacement<br />

A loss or reduction of power causes a full or partial shutdown of the<br />

switch.<br />

Type the show sysfails command at the terminal to determine which<br />

of the power supplies has failed.<br />

Type the non-privileged command clear sysfails after replacing a<br />

power supply to reset the show sysfails command.<br />

<strong>6000</strong> <strong>Switch</strong>>#>clear sysfails<br />

The system failure area has been cleared.<br />

Caution<br />

If the switch has two power supplies, place the replacement<br />

in the empty power-supply bay before removing<br />

one of the power supplies. This prevents the switch<br />

from powering down during hot swap of the power supplies.<br />

Power Supply<br />

Capture Panel<br />

To replace a power supply<br />

1 Loosen the capture panel screws on the front of the power supply.<br />

2 Using the handle, pull out the power supply with one hand and<br />