ELK-M1G QUICK REFERENCE - MENU PROGRAMMING<br />

Menu 01 Menu 04 Menu 06 Menu 07 Menu 08 Menu 10 Menu 13<br />

Bus Mod Enroll Keypad Defs Cutoff Timers Global Options (cont.) Telephone #’s & Accts Zone Rpt Codes User Rpt Codes<br />

Keypad 1 (1) Burglar (26) Out 2 Change to Voltage Telephone #1 Zone #1 User #1<br />

Enrolling (1) Area Assgn (2) Fire (27) Out 2 Delay Time (1) Always Report Alarm Code (1) Open Code<br />

-Disp Totat Modules (2) Silent Entry (3) Medical (28) Out 2 Sgl Alarm Lockout (2) Number Restore Code Close Code<br />

-Allow Module Edit (3) Silent Exit (4) Police (29) Rings til Answer (3) Format Bypass Code<br />

(4) Silent Chime (5) Carbon Mon (30) Ring/Hang/Answer (4) Attempts Trouble Code User 100<br />

Menu 02 (5) Dark in 60 sec (6) Emergency (31) 2 Way Listen-in Enable (5) Acct #1 - Installer-<br />

User Code Auth. (6) Show Date/Time (7) Freeze (32) 2 Way Callback Time (6) Acct #2 Menu 11 (1) Open Code<br />

User 1 (7) Show Temp (8) Gas (33) CS Alm Verify Time (7) Acct #3 Keypad Close Code<br />

(1) Area # (8) Show Area (9) Heat (34) Baud Rate Port 0 (8) Acct #4 Report Codes<br />

(2) Arm (9) Byp Req Code (10) Water (35) Xmit Event Log (9) Acct #5 Keypad 1 User 101<br />

(3) Disarm (10) F1 Key Def. (11) Aux1 24hr (36) Xmit Zone Changes (10) Acct #6 (1) F1 Key Alarm - RP Computer<br />

(4) Bypass (11) F2 Key Def (12) Aux2 24hr (37) Xmit Output Changes (11) Acct #7 (2) F2 Key Alarm Upload/Download<br />

(5) Access (12) F3 Key Def (38) Xmit Task Changes (12) Acct #8 (3) F3 Key Alarm (1) Open Code<br />

(6) Temporary (13) F4 Key Def (39) Xmit Light Changes (13) Report Area/Alm (4) F4 Key Alarm Close Code<br />

(7) Master (14) F5 Key Def Menu 07 (40) Xmit Keypad Keys /Rest/Unbypass (5) F5 Key Alarm<br />

(8) Menu 1-5 (15) F6 Key Def Global Options (41) Req Code User Menus 1-5 (14) Report Zn Bypass (6) F6 Key Alarm Menu 14<br />

(9) Duress (16) [Name] (1) Tel Remote (42) Local Prog. Code (15) Report Zn Troubles Wireless Defs<br />

(10) [Name] (2) 12hr TimeDisp (43) Serial Number [Read Only] (16) Report User Op/Cl 1: ReceiverOptions<br />

(3) DD/MM Disp. (44) Software Ver. [Read Only] (17) Report Sys Globals (1) Receiver Size<br />

Menu 03 Menu 05 (4) Celcius Disp. (45) Default Control Options (18) [Name] (2) ZnBank(Start Zn)<br />

Area Defs Zone Defs (5) DST Observe (81) Default User Codes (3) Reg Supv. Hrs.<br />

Area 1 Zone 1 (6) Fast Loop Tm (82) Default Areas Data Menu 09 Menu 12 (4) Fire Supv. Hrs.<br />

(1) Exit Delay 1 (1) Definition (7) SlowLoop Tm (83) Default Keypads Data Area Report Codes System Rpt Codes 2: Transmitter Opts<br />

(2) Entry Delay 1 (2) Type (8) Cross SelfVer (84) Default Zones Data Area 1 (1) AC Fail Delay ^ Select Transmitter<br />

(3) Exit Delay 2 (3) Area Assign (9) Cross Zn Tm (85) Default Zone Names (1) Dial Delay Time (2) AC Fail Code (1) Enable Xmtr.<br />

(4) Entry Delay 2 (4) Silent Alarm (10) Aud Trbls (86) Default Cutoff Timers (2) Abort Code (3) Auto Test Code (2) Supv. Type<br />

(5) Auto Stay (5) Dialer Delay (11) 6 digit codes (87) Default Global Data (3) Cancel Time (4) TstTime hr:mm (3) Enable Option 1<br />

(6) Exit Restart (6) Listen-In (12) CodeLockout (88) Default Telephone Data (4) Cancel Code (5) Days betweenTest (4) Enable Option 2<br />

(7) Closing Ringback (7) Bypass (13) Common Area (89) Default Telephone Numbers (5) Close Auto (6) Aux Overcurrent (5) Keyfob User ID<br />

(8) SglKey Quickarm (8) Force Arm (14) Out1 Yelp to Buz (90) Default Area Report Codes (6) Close Early (7) Exp Module Tbl 3: Learn Transmitter<br />

(9) DblKey Quickarm (9) Swinger (15) Out1 Start Vol. (91) Default Zone Report Codes (7) Close Extended (8) Installer Begin ^ Select Transmitter<br />

(10) StayKeyScroll (10) Per. Trip (16) Out1 Max. Alm. (92) Default System Report Codes (8) Fail to Close (9) Installer End (1) Xmtr to Learn<br />

(11) Stay Instant (11) Fast Loop (17) Out1 Max. Voice (93) Default User Report Codes (9) Late Close (10) Log 80% Full (2) Push Xmtr<br />

(12) Night Scroll (12) Chime (18) Out1 Max. NonAlm (94) Default Voice Messages (10) Keyswitch Close (11) Low Battery 4: Keyfob Event Def.<br />

(13) Night Instant (13) Cross Zn (19) Out1 ‘No Talk’ (95) Default Wireless Definitions (11) Duress Code (12) Memory Error (1) Button 1 Code<br />

(14) StayChgArmed (14) [Name] (20) Out1 Say Sys (99) Default Entire Control Panel (12) Open After Alarm (13) RP Download (2) Button 2 Code<br />

(15) [Name] (21) Out1 Say Alms (13) Open Early (14) Tel Line Fault (3) Button 3 Code<br />

(22) Out1 Say Zn Status (14) Fail to Open (15) Output 2 Tbl (4) Button 4 Code<br />

(23) Out1 Say Sys Tbl (15) Open Late (5) Button 5 Code<br />

(24) Out1 Say Zn Tbl (16) Keyswitch Open (6) Button 6 Code<br />

(25) Out1 Say Chime (17) User Lockout (7) Button 7 Code<br />

(18) Exit Error (8) Button 8 Code<br />

(19) Fail to Comm<br />