Electrical system 9<br />
9.6.1 Battery cut-off switch<br />
When the battery cut-off switch is OFF, the safety/drainage valve opens.<br />
<br />
The water flows out of the boiler.<br />
Also switch off a refrigerator with automatic power selection system. The<br />
<br />
refrigerator will otherwise switch to gas operation.<br />
After switching the battery cut-off switch back on again: Put the basic light<br />
<br />
(lighting in the entrance area), entrance step, heater and spare 4 back into<br />
service (depending on the model). To do so, switch on the 12 V main switch<br />
briefly. This also applies if the living area battery was disconnected and<br />
then reconnected.<br />
The battery cut-off switch disconnects all the living area 12 V appliances, even<br />
the safety/drainage valve. This prevents the living area battery from slowly discharging<br />
if the vehicle is not used for a longer period of time (e.g. temporary<br />
lay-up).<br />
The batteries can still be charged by the transformer/rectifier when the battery<br />
cut-off switch is turned off.<br />
Switching on/off:<br />
Press the battery cut-off switch up: Battery ON.<br />
<br />
Press the battery cut-off switch down: Battery OFF.<br />
<br />
9.6.2 Battery selector switch<br />
If the battery selector switch is set incorrectly, there is the danger of the<br />
formation of detonating (oxy-hydrogen gas). Danger of explosion!<br />
Incorrect setting of the battery selector switch damages the living area battery.<br />
<br />
The factory settings of the battery selector switch must not be changed.<br />
<br />
The battery selector switch is used to set the charger module in the transformer/rectifier<br />
to the type of living area battery installed in the vehicle ("lead<br />
acid" or "dryfill" battery).<br />
9.6.3 Battery monitor<br />
You must fully recharge a discharged living area battery as soon as possible.<br />
<br />
The battery monitor in the transformer/rectifier monitors the voltage in the<br />
living area battery.<br />
If the battery voltage falls below 10.5 V, the battery monitor in the transformer/<br />
rectifier switches off all of the 12 V appliances, excluding the safety/drainage<br />
valve.<br />
A refrigerator with automatic power selection system switches to gas operation.<br />