Service - 166<br />

Trencher<br />

<strong>RT120Q</strong> Operator’s <strong>Manual</strong><br />

50 Hour<br />

Check Trencher Gearbox Oil Level<br />

Check oil at sight tube every 50 hours. Keep oil<br />

level at horizontal line on housing. If necessary,<br />

add MPL at fill plug.<br />

Plow<br />

Change Plow Vibrator Oil<br />

Hot parts may<br />

cause burns. Do not touch until<br />

cool.<br />

Change plow vibrator oil after first 50 hours of<br />

operation. Drain oil at drain plug (2). Replace<br />

plug and move plow vibrator to horizontal<br />

position. Add MPL at fill (1) until oil is halfway up<br />

sight glass (2). Refill capacity is 4 qt (3.8 L).