APPENDIX 7: REQUIREMENTS FOR GENETIC MODIFICATION BIOASFETY LEVEL<br />

2 (GM-BSL2)<br />

The requirements listed here for GM-BSL2 containment emphasise the procedures to<br />

be observed by the laboratory worker to ensure a basic level of laboratory safety. There<br />

are also some architectural requirements relating to laboratory design and equipment.<br />

The requirements for <strong>Biosafety</strong> Level 2 in the Laboratory <strong>Biosafety</strong> Manual (3 rd Ed,<br />

WHO) and the OSH <strong>Guidelines</strong> for Laboratories and Production Facilities in the<br />

Biomedical Sciences Industry shall apply for GM-BSL2. In addition, the following<br />

requirements must be included.<br />

Laboratory Procedures<br />

Many of the laboratory procedures detailed below are those that would be considered<br />

essential minimum practices in any microbiological laboratory.<br />

1. Storage of food or drink in the laboratory or any storage unit containing<br />

genetically manipulated DNA (e.g. refrigerator) is prohibited.<br />

2. Equipment used for handling cultures or contaminated material which is not<br />

readily steam sterilised shall be chemically disinfected after use.<br />

3. All technical procedures shall be performed in a way that minimises the creation<br />

of aerosols. In particular, operations such as sonication or vortexing which may<br />

generate aerosols are to be done in a biological safety cabinet. A period of at<br />

least five minutes shall be allowed for aerosols to settle before opening<br />

homogeniser or sonicator containers in a biological safety cabinet.<br />

Essential Equipment<br />

Each laboratory shall be equipped with basin mixers for hand washing, preferably footoperated,<br />

elbow-operated or electronically operated. Emergency drench showers and<br />

eyewash stations shall be provided.<br />

Laboratory Signs<br />

The laboratory shall be labelled with adhesive signs:<br />

• on the door, with a sign designating the level of containment;<br />

• in the laboratory, with a sign giving procedures required for work at this level of<br />

containment.<br />

The signs for laboratories shall be put up only after inspection by the relevant<br />

regulatory agency for all higher levels of containment.<br />

Constant Temperature Rooms<br />

Walk-in warm rooms and cold rooms used for incubation or storage of genetically<br />

manipulated material may be certified as GM-BSL2 facilities even if they do not contain<br />

sinks or coat hooks. Work in such rooms shall otherwise follow all the procedures<br />

required for GM-BSL2 laboratories.<br />