MAINTENANCE INSTRUCTIONS<br />
INSTRUCTIONS FOR MAINTENANCE<br />
OF DRY AIR CLEANER<br />
Carry out maintenance of the air cleaner<br />
as follows:<br />
1. Lift the front bonnet.<br />
2. Release clips of the air cleaner lid<br />
(marked by arrows).<br />
3. Remove the cleaner lid (1).<br />
X712 G713 QQQ_G714<br />
REGENERATION OF THE MAIN AIR<br />
CLEANER CARTRIDGE<br />
Pull out the main cartridge of the dry<br />
cleaner (2).<br />
Unless the main cartridge is damaged<br />
(no dust may be on the inner surface of<br />
the cartridge), carry out regeneration by<br />
purging using compressed air from the<br />
inner side of the cartridge.<br />
This cleaning procedure may be repeated<br />
maximum three times. The cartridge<br />
shall be replaced every year.<br />
REPLACEMENT OF AIR CLEANER<br />
LOCKING CARTRIDGE<br />
Pull out the locking cartridge of the dry<br />
cleaner (3).<br />
The locking cartridge cannot be<br />
regenerated. It shall always be<br />
replaced in these cases:<br />
- when the main cartridge is<br />
damaged<br />
- after 5 maintenances of the air<br />
cleaner<br />
- at least every two years<br />