DM5 & DM6<br />
FEATURES • SPECIFICATIONS • DIMENSIONS • ORDERING<br />
OPEN LOOP BRUSHED DCDRIVE<br />
DRIVES<br />
DM open loop, brushed DC motor drive modules are available<br />
with two different power supply options. Available in open chassis<br />
configuration, DMs can be ordered as part of a complete, matched<br />
Axidyne Dc Control <strong>System</strong> (with controller, motor <strong>and</strong> actuator) or<br />
separately for use with customer-provided control systems. Four<br />
inputs (On/Off, Brake, Fwd/Rev, Enable) are available for use with a<br />
<strong>Tol</strong>-O-<strong>Matic</strong> or customer-supplied controller, a PLC, or with manual<br />
control from separately-mounted switches. Speed control can be provided<br />
by a potentiometer or dc analog voltage input. Inputs are optically<br />
isolated for transient voltage protection<br />
<strong>and</strong> noise<br />
immunity to help<br />
simplify integration<br />
into almost all control<br />
environments.<br />
Features<br />
• Choice of two power rating configurations (matched to Axidyne dc motor ratings).<br />
• Open-chassis configuration<br />
• Self resetting fuse for dc supply to drive<br />
• Jumper selectable speed control with potentiometer or 1.5 to 4.1 V.dc analog signal<br />
from PLC or controller modules<br />
• Optional solid state dynamic braking circuitry for accuracy <strong>and</strong> consistency<br />
• Lockout fault protection for dc power supply output under-voltage<br />
• Adjustable current trip level for over current (overload condition) protection<br />
• Fault condition (lock out) output for L.E.D.<br />
• L.E.D. status indicators for enabled <strong>and</strong> fault (open-chassis configuration only)<br />
• Independent acceleration <strong>and</strong> deceleration adjustment (0 to 7.0 seconds)<br />
• Inhibit drive using Enable input for immediate dc drive shut down<br />
48<br />
SPECIFICATIONS<br />
SPECIFICATIONS<br />
DM Open Loop<br />
Brushed DC Drive Module<br />
Power<br />
Input Current (AC line): 115 Vac/60 Hz (85-128 Vac range)<br />
DM5 Output Voltage: 32 Vdc<br />
DM5 Continuous Current: 15 Amp<br />
DM6 Output Voltage: 48 Vdc<br />
DM6 Continuous Current: 10 Amp<br />
DM5, DM6 Peak Current: 30 Amp (5 millisecond rating)<br />
DM5, DM6 Max. Power: 480 Watts<br />
P.W.M<br />
Frequency 20 kHz<br />
% P.W.M. vs Potentiometer 0% PWM @ 1.5 Vdc to<br />
Voltage Reference 100% PWM @ 4.1 Vdc<br />
Auxiliary Speed Control<br />
Potentiometer Range: 10K Ω range for externally provided potentiometer<br />
(included with drive)<br />
Analog input: 1.5 to 4.1 Vdc<br />
Accel./Deceleration Range: 0 to 7.0 seconds<br />
Over-Current Trip Setting<br />
Environment<br />
Potentiometer:<br />
Delay:<br />
25 turn potentiometer adjustable to 125% of<br />
rating<br />
0.2 second delay / self adjusting for accel.<br />
Temperature Range: 32° to 122° F (0° to 50° C)<br />
Humidity: 10 - 95% non-condensing<br />
Reset: Normally closed momentary reset input.<br />
Fault Indicator<br />
L.E.D.: on Drive<br />
OUTPUT: for external L.E.D.<br />
Drive Module Optically-Isolated Inputs•<br />
On/Off:<br />
Brake:<br />
Fwd/Rev:<br />
Enable:<br />
Initiates acceleration or deceleration profile<br />
Stopping of motor with dynamic braking<br />
Reversing motor direction<br />
Disabling or enabling power to the drive<br />
Fault Reset - Clears current trip fault<br />
•Dc voltage supply (5 to 25 Vdc/25 mA. max.) required to power Drive<br />
Module opto-isolation when NOT used with Basic Controller Module.