FLENDER Standard Couplings - DS TECH
FLENDER Standard Couplings - DS TECH
FLENDER Standard Couplings - DS TECH
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>FLENDER</strong> <strong>Standard</strong> <strong>Couplings</strong><br />
Fluid <strong>Couplings</strong> — FLUDEX Series<br />
General information<br />
© Siemens AG 2011<br />
Selection of FLUDEX type<br />
Listed in the catalog are FLUDEX couplings with pulley, brake<br />
drum, brake disk and flexible N-EUPEX coupling.<br />
Further types, e.g. in combination with a torsionally rigid steel<br />
Series Type Add-on coupling Characteristic feature<br />
FA<br />
-without delay chamber<br />
-impeller-driven<br />
-Starting torque: T max = 2.0 x T eff<br />
-Starting aid for standard motors and<br />
torsional vibration isolation<br />
FG<br />
-without delay chamber<br />
-Housing-driven<br />
-Starting torque: T max = 2.0 x T eff<br />
-Starting aid for standard motors, for<br />
torsional vibration isolation and for overload<br />
limitation in the event of drive blockage.<br />
FV<br />
-with delay chamber<br />
-Housing-driven<br />
-Starting torque: T max = 1.5 x T eff<br />
-Starting aid for motors and soft-starting of<br />
conveyor equipment<br />
FN<br />
-with large delay chamber<br />
-Housing drive via hub carrier<br />
-Starting torque: T max = 1.3 x T eff<br />
-Starting aid for motors with very unfavorable<br />
characteristic and soft-starting of empty<br />
and full conveying equipment<br />
-favorable weight distribution on brake-drum<br />
variant<br />
The maximum shaft misalignments permissible for an N-EUPEX<br />
add-on coupling are shown in catalog section 7. For greater<br />
shaft misalignments FLUDEX couplings can be combined with<br />
cardan shafts or other displacement couplings.<br />
membrane coupling of the ARPEX series or a highly flexible coupling<br />
of the ELPEX or ELPEX-S series, are available.<br />
FAO Without Basic coupling with connecting flange<br />
FAR Without with attached pulley<br />
FAD N-EUPEX D 1)<br />
FAE N-EUPEX E enables larger bores on the output side<br />
FAM N-EUPEX M enables a short fitting length<br />
FADB N-EUPEX D with brake drum<br />
FA<strong>DS</strong> SB N-EUPEX D<br />
1) with brake disk for stopping brakes<br />
FA<strong>DS</strong> HB N-EUPEX D<br />
1) with brake disk for blocking brakes<br />
FGO Without Basic coupling with connecting flange<br />
FGD N-EUPEX D<br />
1)<br />
FGE N-EUPEX E enables larger bores on the output side<br />
FGM N-EUPEX M enables a short fitting length<br />
FVO Without Coupling with connecting flange<br />
FVD N-EUPEX D 1)<br />
FVE N-EUPEX E enables larger bores on the output side<br />
FVM N-EUPEX M enables a short fitting length<br />
FNO Without Coupling with connecting shaft<br />
FNA N-EUPEX A<br />
1) enables a short fitting length<br />
FND N-EUPEX D 1) 2)<br />
FNDB N-EUPEX D<br />
1) 2) with brake drum<br />
FN<strong>DS</strong> SB N-EUPEX D<br />
1) 2) with brake disk for stopping brakes<br />
FN<strong>DS</strong> HB N-EUPEX D 1) 2) with brake disk for blocking brakes<br />
(450) 655-7447<br />
info@pt-dstech.com<br />
www.dstech.ca<br />
13<br />
1275 Newton, local 15<br />
Boucherville, Qc,<br />
Canada, J4B 5H2<br />
1) Enables change of flexible elements without moving the machines<br />
axially.<br />
2) Enables the coupling to be fitted or dismounted without displacing the<br />
coupled machines.<br />
13/10 Siemens MD 10.1 · 2011