25.01.2015 Views

FLENDER Standard Couplings - DS TECH

FLENDER Standard Couplings - DS TECH

FLENDER Standard Couplings - DS TECH

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>FLENDER</strong> <strong>Standard</strong> <strong>Couplings</strong><br />

Fluid <strong>Couplings</strong> — FLUDEX Series<br />

Special types<br />

© Siemens AG 2011<br />

■ Selection and ordering data<br />

Selection of additional ordering data<br />

Special types<br />

Oil filling<br />

Without oil filling and without oil filling quantity specification stamped on the coupling<br />

With oil filling (specification of oil filling quantity “+Y90” required)<br />

With specification of oil filling quantity<br />

Thermal equipment<br />

<strong>Standard</strong> type (fuse 140 °C, seal set Perbunan)<br />

Fuse 110 °C, seal set Perbunan<br />

Explosion protection in conformity to 94/9EG ATEX100A, seal set Perbunan<br />

Thermal switch 110 °C, fuse 140 °C, seal set Perbunan (option not available with size 222)<br />

EOC transmitter 125 °C, fuse 160 °C, seal set Perbunan (option not available with size 222)<br />

Explosion protection in conformity to 94/9EG ATEX100A, seal set Viton<br />

Fuse 110 °C, seal set Viton<br />

Fuse 140 °C, seal set Viton<br />

Fuse 160 °C, seal set Viton<br />

Thermal switch 110 °C, fuse 140 °C, seal set Viton (option not available with size 222)<br />

Thermal switch 140 °C, fuse 160 °C, seal set Viton (option not available with size 222)<br />

EOC transmitter 125 °C, fuse 160 °C, seal set Viton (option not available with size 222)<br />

Accessories for thermal monitoring equipment<br />

With switchgear<br />

With sensor and evaluation instrument<br />

For preservation, see catalog section 3<br />

Drive<br />

<strong>Standard</strong> drive side<br />

FA series with housing drive<br />

FG/FV/FN series with impeller drive<br />

Position<br />

Horizontal version<br />

Vertical version, motor overhead (option not permitted in FV and FN series)<br />

Vertical version, motor underneath<br />

Additional ordering data -Z with<br />

order code and, if necessary with<br />

plain text specification<br />

Without addition – standard<br />

F16<br />

Y90 • and orderer specification<br />

Without addition – standard<br />

F01<br />

F02<br />

F03<br />

F04<br />

F06<br />

F05<br />

F07<br />

F08<br />

F10<br />

F11<br />

F12<br />

F25<br />

F26<br />

Without addition – standard<br />

F23<br />

F24<br />

Without addition – standard<br />

F13<br />

F14<br />

(450) 655-7447<br />

info@pt-dstech.com<br />

www.dstech.ca<br />

13<br />

1275 Newton, local 15<br />

Boucherville, Qc,<br />

Canada, J4B 5H2<br />

13/48 Siemens MD 10.1 · 2011