25.01.2015 Views

FLENDER Standard Couplings - DS TECH

FLENDER Standard Couplings - DS TECH

FLENDER Standard Couplings - DS TECH

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

© Siemens AG 2011<br />

<strong>FLENDER</strong> <strong>Standard</strong> <strong>Couplings</strong><br />

Fluid <strong>Couplings</strong> — FLUDEX Series<br />

General information<br />

Selection of FLUDEX size<br />

FA series<br />

The FLUDEX size is determined by the output to be transmitted<br />

in comparison with the rated outputs listed in the following tables.<br />

No application factors or additional safety factors need be<br />

taken into consideration. The rated outputs stated in the tables<br />

normally require the maximum permissible filling (80 % to 85 %)<br />

of the coupling and because of operating slip, lead to the coupling<br />

heating up by approx. 50 °C relative to the ambient (cooling<br />

air) temperature. With lower outputs, coupling heating will be<br />

proportionately lower. If for continuous operation of the coupling<br />

an absolute temperature (ambient temperature + coupling heating)<br />

of > 85 °C is expected, the coupling must be fitted with FPM<br />

seals and 160 °C fusible safety plugs.<br />

Speed in rpm<br />

600 740 890 980 1180 1350 1470 1600 1770 2000 2300 2600 2950 3550<br />

Rated output P N in kW<br />

Size<br />

1.2 1.6 2.8 4.2 5.5 6.9 8.7 11.7 15 19 24 33 222<br />

1.2 2.3 4 5.5 9 14 18.5 23 29 37 48 60 70 90 297<br />

2.6 4.8 8.7 11.5 18 27 34 40 51 65 82 97 120 145 342<br />

5.7 10 16 21 36 49 61 74 87 105 135 165 180 395<br />

11 21 32 41 65 90 110 127 155 190 230 290 370 450<br />

19 36 60 75 115 154 190 215 260 310 395 516<br />

37 69 109 134 200 260 320 360 435 540 590<br />

FG, FV and FN series<br />

1275 Newton, local 15<br />

Boucherville, Qc,<br />

Canada, J4B 5H2<br />

Speed in rpm<br />

600 740 890 980 1180 1350 1470 1600 1770 2000 2300 2600 2950 3550<br />

Rated output P N in kW<br />

Size<br />

4 7.5 12 16 26 38 48 61 85 110 140 170 220 290 370<br />

7.5 15 23 30 48 70 90 115 140 175 220 280 340 425<br />

15 30 45 58 95 140 180 210 245 300 380 480 490<br />

28 55 85 110 180 255 300 350 420 525 660 565<br />

55 110 170 220 350 450 520 600 730 900 655<br />

110 210 330 440 600 760 870 1010 1220 755<br />

240 440 700 810 1130 1440 1660 887<br />

480 880 1400 1600 2000 2350 2500 887D 1)<br />

The specified coupling weights of the following selection tables are effective for maximum bores without oil filling.<br />

13<br />

(450) 655-7447<br />

info@pt-dstech.com<br />

www.dstech.ca<br />

1)<br />

D = double-flow variant on request.<br />

Siemens MD 10.1 · 2011<br />