3.6 Equipment<br />

Instructions<br />

Please complete the following tables indicating quantity and engineering work-hours for the<br />

categories appropriate to your project. If you cannot enter all data then enter totals only. Include<br />

rework in the work-hours only. If the project had no work-hours or quantities for a category,<br />

enter none.<br />

The Total Quantity <strong>of</strong> equipment is the amount <strong>of</strong> tagged items provided in the final Issued for<br />

<strong>Construction</strong> (IFC) drawings with vendor designed skids being counted as a single item. The<br />

Individually Designed quantity is the quantity defined by unique data sheets. For example, pump<br />

P201a/b is one unique data sheet, but is a total <strong>of</strong> two items.<br />

These hours include only mechanical discipline hours.<br />

Refer to the section “Instructions for Computation <strong>of</strong> Work-Hours and Rework-Hours” for an<br />

additional detailed listing <strong>of</strong> direct hours to be included and indirect hours that are to be excluded<br />

from the computation <strong>of</strong> the work-hours.<br />

Which design platform was used for this category in this project? Check all that apply.<br />

2D ( )<br />

3D ( )<br />

Pressure Vessels<br />

None<br />

Individually<br />

Designed<br />

(each)<br />

Total<br />

Quantity<br />

(each)<br />

Engineering WH<br />

(including rework)<br />

(hours)<br />

This includes tray/packed towers, columns, reactors/regenerators, and miscellaneous other<br />

pressure vessels.<br />

Field fabricated towers, columns, reactors and regenerators are to be included.<br />

Atmospheric Tanks<br />

None<br />

Individually<br />

Designed<br />

(each)<br />

Total<br />

Quantity<br />

(each)<br />

Engineering WH<br />

(including rework)<br />

(hours)<br />

This includes storage tanks, floating ro<strong>of</strong> tanks, bins/hoppers/silos/cyclones, cryogenic & low<br />

temperature tanks and miscellaneous other atmospheric tanks.<br />

Heat Transfer<br />

Equipment<br />

None<br />

Individually<br />

Designed<br />

(each)<br />

Total<br />

Quantity<br />

(each)<br />

Engineering WH<br />

(including rework)<br />

(hours)<br />

This includes heat exchangers, fin fan coolers, evaporators, cooling towers and<br />

miscellaneous other heat transfer equipment.<br />