MAGNETIC FILTER<br />

> Clarimag 10<br />

Usage mode:<br />

Clarimag 10 is suitable for protecting installations by chemical anticorrosive conditioning<br />

and oxide particles’ magnetic capturing and removal, because these can cause closures,<br />

disorders or damages (maximal flow rate 10 m³/h).<br />

Properties:<br />

- Stainless steel filter 316 I<br />

- Working pressure 10 bar<br />

- Maximal temperature 80 °C<br />

Equipment:<br />

Clarimag 10 manual equipped with:<br />

- 2 pc. 1¼“ connections - 1 pc. 1“ ball valve<br />

- 1 pc. 1“ evacuation device - 1 pc. automatic fan<br />

- 2 pc. 1¼“ ball valves - 1 pc. flow rate regulator<br />

- 1 orifice for introducing the chemical substances in the circuit <strong>of</strong> the central heating plant<br />

Clarimag 10 semi-automatic equipped with:<br />

- 2 pc. 1¼“ connections<br />

- 1 pc. 1“ evacuation device<br />

- 2 pc. 1¼“ ball valves<br />

- 1 pc. 1“ ball valve<br />

- 1 pc. automatic fan<br />

- 1 1 orifice for introducing the chemical substances in the circuit <strong>of</strong> the central heating plant<br />

- 1 pc. flow rate regulator<br />

- a probe stick for pH-value measuring + glove (for setting the probe stick)<br />

- a pH-metric dosing <strong>pump</strong> + tank + injector<br />

- a non-return valve<br />

Clarimag 10 automatic equipped with:<br />

- 2 pc. 1¼“ connections - 1 pc. 1“evacuation device<br />

- 2 pc. 1¼“ electric valve - 1 motor valve for the 1“ evacuation device<br />

- 1 pc. automatic fan - 1 electrical jack<br />

- 1 pc. flow rate regulator - a non-return valve<br />

- a control box - mounted on a rack<br />

- a tank for capturing mud<br />

- a probe stick for pH-value measuring + glove (for setting the probe stick)<br />

- a pH-metric dosing <strong>pump</strong> + tank + injector<br />

- 1 orifice for introducing the chemical substances in the circuit <strong>of</strong> the central heating plant<br />

Tank for mud collection<br />

A 30 or 60 l tank with 2 medium filter and a PVC evacuation valve.<br />

Ref. Product<br />

3954 Clarimag 10 manuel<br />

3955 Clarimag 10 semi-automatic<br />

3956 Clarimag 10 automatic<br />

3957 30 l mud collector<br />

3958 60 l mud collector<br />