MAGNETIC FILTER<br />
> Clarimag 10<br />
Usage mode:<br />
Clarimag 10 is suitable for protecting installations by chemical anticorrosive conditioning<br />
and oxide particles’ magnetic capturing and removal, because these can cause closures,<br />
disorders or damages (maximal flow rate 10 m³/h).<br />
Properties:<br />
- Stainless steel filter 316 I<br />
- Working pressure 10 bar<br />
- Maximal temperature 80 °C<br />
Equipment:<br />
Clarimag 10 manual equipped with:<br />
- 2 pc. 1¼“ connections - 1 pc. 1“ ball valve<br />
- 1 pc. 1“ evacuation device - 1 pc. automatic fan<br />
- 2 pc. 1¼“ ball valves - 1 pc. flow rate regulator<br />
- 1 orifice for introducing the chemical substances in the circuit <strong>of</strong> the central heating plant<br />
Clarimag 10 semi-automatic equipped with:<br />
- 2 pc. 1¼“ connections<br />
- 1 pc. 1“ evacuation device<br />
- 2 pc. 1¼“ ball valves<br />
- 1 pc. 1“ ball valve<br />
- 1 pc. automatic fan<br />
- 1 1 orifice for introducing the chemical substances in the circuit <strong>of</strong> the central heating plant<br />
- 1 pc. flow rate regulator<br />
- a probe stick for pH-value measuring + glove (for setting the probe stick)<br />
- a pH-metric dosing <strong>pump</strong> + tank + injector<br />
- a non-return valve<br />
Clarimag 10 automatic equipped with:<br />
- 2 pc. 1¼“ connections - 1 pc. 1“evacuation device<br />
- 2 pc. 1¼“ electric valve - 1 motor valve for the 1“ evacuation device<br />
- 1 pc. automatic fan - 1 electrical jack<br />
- 1 pc. flow rate regulator - a non-return valve<br />
- a control box - mounted on a rack<br />
- a tank for capturing mud<br />
- a probe stick for pH-value measuring + glove (for setting the probe stick)<br />
- a pH-metric dosing <strong>pump</strong> + tank + injector<br />
- 1 orifice for introducing the chemical substances in the circuit <strong>of</strong> the central heating plant<br />
Tank for mud collection<br />
A 30 or 60 l tank with 2 medium filter and a PVC evacuation valve.<br />
Ref. Product<br />
3954 Clarimag 10 manuel<br />
3955 Clarimag 10 semi-automatic<br />
3956 Clarimag 10 automatic<br />
3957 30 l mud collector<br />
3958 60 l mud collector<br />
23