PRODUCT MANUAL<br />

55 WWAATTEERR//DDAAMMPP--PPRROOOOFFIINNGG<br />

When the <strong>Quad</strong>-<strong>Lock</strong> <strong>Building</strong> System is used for below grade occupied areas or connected to these areas in soils prone<br />

to water saturation and the presence of hydrostatic pressure, the application of exterior waterproofing is necessary.<br />

In addition, always ensure that below grade <strong>Quad</strong>-<strong>Lock</strong> walls are not subject to excessive hydrostatic pressure by<br />

following usual and customary building practices, including but not limited to:<br />

• Proper collection and diversion of rainwater from roofs and surrounding areas.<br />

• Proper construction of footing drains, with rated piping, drainage materials and filter fabric.<br />

• Proper grading of soils away from the building.<br />

• Use of rated free draining backfill material with known flow rates.<br />

• Proper compaction methods during backfill to prevent settling after the fact.<br />

Membrane-type waterproofing products are available as self-adhesive “peel and stick” type (recommended), roll-on, or<br />

spray-on type. Spray-on or roll-on membranes may not adequately bridge joints and other gaps in the foam, unless rated<br />

to do so. <strong>Quad</strong>-<strong>Lock</strong> recommends the use of self-adhesive membranes in almost every instance where hydrostatic<br />

pressure is ever likely to occur. In addition, <strong>Quad</strong>-<strong>Lock</strong> recommends a drainage/protection board layer to adequately<br />

drain the soil, and to protect the membrane from backfill materials.<br />

For soil conditions that are never prone to saturation by water and the resulting hydrostatic pressure, damp-proofing<br />

measures may be adequate. <strong>Quad</strong>-<strong>Lock</strong> recommends the use of a drainage/protection board layer to isolate the wall<br />

from any potential ground water or run off. A spray-on or roll-on water based emulsion can be used in this case, but must<br />

be compatible with EPS foam and adequately bridge joints and other gaps in the foam. No petroleum based<br />

compounds can be used. Consult the manufacturer of the damp-proofing agent to determine its compatibility with EPS<br />

and ICFs.<br />

Below is a list of readily available water- and damp-proofing products. Check for compatibility of the product and warranty<br />

availability with the manufacturer of that product prior to applying it to the <strong>Quad</strong>-<strong>Lock</strong> Panels. <strong>Quad</strong>-<strong>Lock</strong> <strong>Building</strong><br />

<strong>Systems</strong> does not extend any warranties on the waterproofing abilities of the <strong>Quad</strong>-<strong>Lock</strong> system.<br />

Water/Damp-Proofing – Recommended Products<br />

PRODUCT NAME MANUFACTURER TYPE APPLICATION<br />

Blueskin WP-200 BAKOR 604-533-2608<br />

19914 68 th Avenue<br />

Langley, BC<br />

Colphene ICF Soprema Inc. 604-522-3944<br />

450 Derwent Place<br />

New Westminster, BC V3M 5Y9<br />

Jiffy Seal<br />

140/160<br />

Bituthene 4000<br />

Bituthene 3000<br />

Melrol<br />

Melgard<br />

Protecto Wrap Co. 800-759-9727 or<br />

2255 S Delware 383-777-3001<br />

Denver, CO 80223<br />

W.R. Grace & Co. 617-876-1400<br />

62 Whitmore Ave.<br />

Cambridge, MA 02140<br />

W.R. Meadows Co. 708-683-4500<br />

PO Box 543<br />

Legion, IL 60121<br />

Delta-MS Clear Cosella-Dörken Products, Inc.<br />

4655 Delta Way<br />

Beamsville, ON L0R 1B4<br />

888-444-5824<br />

System Platon Big ‘O’ Inc.<br />

Exeter, ON<br />

800-265-7622<br />

Waterproofing<br />

Membrane<br />

Waterproofing<br />

Membrane<br />

Waterproofing<br />

Membrane<br />

Waterproofing<br />

Membrane<br />

Waterproofing<br />

Membrane<br />

Drainage<br />

Board<br />

Damp-proofing<br />

Membrane<br />

Self-Adhesive<br />

Self-Adhesive<br />

Self-Adhesive<br />

Self-Adhesive<br />

Self-Adhesive<br />

Mechanically<br />

Fastened<br />

Mechanically<br />

Fastened<br />

July 2009 Chapter 5 – Water/Damp-Proofing Page 115