Figure 115: Internal Concrete Vibrator<br />

PRODUCT MANUAL<br />

Standard concrete with a maximum slump of 6" [152mm] can be used to make <strong>Quad</strong>-<strong>Lock</strong> walls free of voids, especially<br />

if internal vibration is used. Slump loss is expected over time, especially in hot weather. Water added to the mix will<br />

decrease the strength and this should not be done. Re-dosing the mix (once) with plasticizer or water reducer is<br />

permissible.<br />

<strong>Building</strong> Tip: A good indication that the concrete is properly consolidated is when water from the concrete mix seeps<br />

out from the bottom of the vertical joints.<br />