18.11.2012 Views

B - Quad-Lock Building Systems

B - Quad-Lock Building Systems

B - Quad-Lock Building Systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

PRODUCT MANUAL<br />

Typical Hollow Core Precast Floor Slab Connection<br />

VERTICAL REINFORCEMENT<br />

AT REQUIRED SPACING<br />

EXTERIOR FINISH AS SPECIFIED<br />

REINFORCED CONCRETE CORE<br />

PARGING MIN. PER CODE<br />

WATERPROOFING AND DRAINAGE<br />

BOARD AS SPECIFED<br />

FREE DRAINING BACKFILL<br />

AS SPECIFIED<br />

QUAD-LOCK TIE<br />

QUAD-LOCK PANEL<br />

SLOPE<br />

Figure 84: Typical Hollow Core Precast Floor Slab Connection<br />

FRAMING CONNECTIONS<br />

INTERIOR FINISH AS SPECIFIED<br />

FLOOR IS INSTALLED PRIOR TO INSTALLING<br />

NEXT STORY OF WALL<br />

HOLLOW CORE PRECAST PANEL SYSTEM<br />

SLAB TOPPING AS SPECIFIED<br />

HOLLOW CORE PANEL REINF.<br />

AS SPECIFIED<br />

ALLOW CONCRETE TO INFIL THE CORE<br />

BY BREKING OUT TOP OF HOLOW CORE<br />

SKIN AT EVERY DOWEL LOCATION<br />

MIN. BEARING & BEARING PAD<br />

AS SPECIFIED<br />

HORIZONTAL REINFORCEMENT<br />

PLACED ALTERNATELY AT<br />

REQUIRED SPACING<br />

When <strong>Quad</strong>-<strong>Lock</strong> walls are used as a basement or foundation only, with conventional framing above, many design<br />

options are available depending on requirements.<br />

<strong>Quad</strong>-<strong>Lock</strong> may be used in conjunction with all conventional building methods. Ledgers, joists, trusses and rafters of<br />

wood or steel may be attached to the <strong>Quad</strong>-<strong>Lock</strong> walls. <strong>Quad</strong>-<strong>Lock</strong> recommends having an Engineer review specific<br />

applications.<br />

July 2009 Chapter 2 – Design & Construction Details Page 81