PRODUCT MANUAL<br />

WINDOW INSTALLATION:<br />

Windows can be attached to rough openings in <strong>Quad</strong>-<strong>Lock</strong> walls in one of several ways:<br />

1. Screw window flanges to stops that are fastened to internal buck-outs. This method will have required oversizing<br />

the rough openings by 2 times the stop material thickness. (Example 1½" + 1½"= 3" [38mm + 38mm = 76mm]) It is<br />

advisable to add a small amount of extra room to insure a fit.<br />

2. Screw windows to “L” metal that has been fastened to bare concrete, left exposed after removal of temporary rough<br />

opening forms. Flangeless windows are generally fastened through the window frame and directly into concrete.<br />

3. Use adhesive and 3¼" [83mm] min. length screws to fasten window flanges to surface of foam, and into internal<br />

buck-out material behind foam panels.<br />

4. Flangeless windows are generally fastened through the window frame and directly into concrete, left exposed after<br />

removal of temporary rough opening forms.<br />

Window Flashing:<br />

When installing windows, <strong>Quad</strong>-<strong>Lock</strong> recommends that proper precautions are made to resist the intrusion of water<br />

through the window opening. In addition to adherence to the window manufacturer’s recommendations, <strong>Quad</strong>-<strong>Lock</strong><br />

makes the following recommendations:<br />

• Window rough openings should be flashed with a durable waterproof flashing material which is rated for contact<br />

with Expanded Polystyrene<br />

• Layers of flashing should be “shingled” from the bottom of the window opening to allow moisture to shed away from<br />

the opening. Flash the sill area first, then install the window with caulking, then the side flashing, and lastly the<br />

head flashing.<br />

• “Peel-and-stick” flashing products should only be installed after a compatible primer is applied to the EPS to<br />

promote adhesion and durability.<br />

• If EIFS or cement-based stucco is to be applied as a finish layer, the surface of the flashing material should be<br />

textured to promote adhesion between the flashing and the cladding product. (Suggest: Polyguard “Tile-Guard”<br />

www.polyguardproducts.com)<br />

Consult the window manufacturer’s installation instructions in all cases and call the <strong>Quad</strong>-<strong>Lock</strong> Technical Department<br />

with questions.<br />

FLOOR CONNECTIONS<br />

<strong>Quad</strong>-<strong>Lock</strong> can accommodate several wall-to-floor connection details, depending on the type of floor system called for by<br />

the building designer, including conventional lumber, engineered wood joist, metal joist, heavy timber, suspended<br />

concrete slab, and concrete T-beam slab construction.<br />

Ledger Connections for Wood Floors<br />

Ledgers may be attached using most generally accepted building practices. Commonly, ledger boards are either pre-set<br />

with bolts or attached using one of several ICF Ledger Connector systems.<br />

ICF Ledger Connectors (ICFLC)<br />

<strong>Quad</strong>-<strong>Lock</strong> distributes the ICF Ledger Connector System from Simpson Strong Tie Co. The system provides easy, quick<br />

and versatile installation of ledgers for use with regular thickness <strong>Quad</strong>-<strong>Lock</strong> Panels. Ledger brackets can also be used<br />

for the attachment of interior walls, overhead door attachment etc.<br />

<strong>Quad</strong>-<strong>Lock</strong> recommends that the ICFLC, ICFLC-W, ICFLC-CW and their associated fasteners should NOT be used in<br />

contact with treated lumber, in exterior applications, or anywhere water is likely to be present (unless you ensure<br />

compatibility of your treated lumber with the metal components).<br />

July 2009 Chapter 2 – Design & Construction Details Page 71