PRODUCT MANUAL<br />

SOLID WALL CAP<br />

In cases where a solid concrete cap is needed on top of a <strong>Quad</strong>-<strong>Lock</strong> wall, such as with retaining walls and some<br />

foundation walls, screw plywood strips to the Metal Track as a form and screed line. Brace as needed.<br />

MAX. = 6" [153mm]<br />

MIN. = 3" [77mm]<br />

FASTEN TO QUAD-LOCK TIES<br />

AS SHOWN<br />

VERTICAL REINFORCEMENT<br />

AT REQUIRED SPACING<br />

QUAD-LOCK TIE<br />

Figure 90: Forming for Solid Wall Cap<br />

CONNECTIONS TO OTHER WALLS<br />

Interior Partition Wall Connection<br />

BEVEL EDGE OF CONCRETE<br />

SECOND FORM LAYER<br />

PLYWOOD FORM SPACER LAYER<br />

TO ALLOW FOR EXTERIOR FINISH<br />

QUAD-LOCK PANEL<br />

HORIZONTAL REINFORCEMENT<br />

PLACED ALTERNATELY AT<br />

REQUIRED SPACING<br />

The methods shown below or the ICF Ledger Connector System (see ICF Ledger Connector on Page 71) can be used<br />

for the attachment of interior walls.<br />

QUAD-LOCK TIE<br />

QUAD-LOCK PANEL<br />

EXTERIOR FINISH AS SPECIFIED<br />

VERTICAL REINFORCEMENT<br />

AT REQUIRED SPACING<br />

Figure 91: Typical Interior Partition Wall Connection (plan view)<br />

HORIZONTAL REINFORCEMENT<br />

PLACED ALTERNATELY AT<br />

REQUIRED SPACING<br />

INTERIOR PARTITION WALL<br />

MASONARY SCREW OR ANCHOR<br />

AS SPECIFIED<br />

INTERIOR FINISH AS SPECIFIED<br />

July 2009 Chapter 2 – Design & Construction Details Page 87