Angular deflecti<strong>on</strong><br />
DN 00 - DN 1000 BLS ® joints<br />
Once the joint has been made, pipes <strong>of</strong> the nominal dimensi<strong>on</strong>s can be deflected to the<br />
following angles:<br />
DN 00 – 2,0°<br />
DN 700 – 1, °<br />
DN 800 – 1, °<br />
DN 900 – 1, °<br />
DN 1000 – 1, °<br />
For a pipe metres in length, an angular deflecti<strong>on</strong> <strong>of</strong> 1° gives a movement <strong>of</strong>f the axis<br />
<strong>of</strong> the pipe fitted previously <strong>of</strong> about ten centimetres, i.e. a deflecti<strong>on</strong> <strong>of</strong> 3° = 30 centimetres.<br />
Notice <strong>on</strong> installati<strong>on</strong> and laying<br />
It should be borne in mind that, because the locking segments adjust as a functi<strong>on</strong> <strong>of</strong> the<br />
internal pressure, stretches <strong>of</strong> up to about eight millimetres per joint may occur.<br />
To allow for the amount by which the pipeline moves outwards when stretched by pressure,<br />
the pipes should be <strong>of</strong>fset inwards at all bends by deflecting the joints inwards to<br />
their maximum permitted angular deflecti<strong>on</strong>. See the diagram below.<br />
Positi<strong>on</strong> after<br />
stretching<br />
Positi<strong>on</strong> when<br />
installed<br />
45°<br />