Fig. 5.3 Assembly <strong>of</strong> the string <strong>of</strong> DN 900 pipes in a floodable trench<br />

Fig. 5.4 The string <strong>of</strong> DN 900 pipes floating in<br />

the trench when flooded<br />

General<br />

After this satisfactory experience, development went ahead at a very rapid pace: In 199<br />

the pipes were <strong>of</strong> DN 00 size [ .2] (Figs. .1 and .2), in 2000 the bar was raised<br />

to DN 00 [ .3] and in 2003 DN 700 pipes were pulled in by the horiz<strong>on</strong>tal directi<strong>on</strong>al<br />

drilling technique in the Netherlands [ . ]. The current record – held by <str<strong>on</strong>g>Buderus</str<strong>on</strong>g><br />

Giesserei Wetzlar GmbH pipes with BLS ® joints and ZMU – is approximately 00 metres<br />

<strong>of</strong> DN 900 pipes in Valencia in Spain (Figs. .3 to . ).<br />

In parallel with this the DVGW was developing technical rules for the technique, and<br />

these took the form <strong>of</strong> Arbeitsblatt GW 321 Steuerbare horiz<strong>on</strong>tale Spülbohrverfahren<br />

für Gas- und Wasserrohrleitungen – Anforderungen, Gütesicherung und Prüfung [Steerable<br />

horiz<strong>on</strong>tal directi<strong>on</strong>al drilling methods for gas and water pipelines – Requirements,<br />

quality assurance and testing], which was published in October 2003 [ . ].<br />

Fig. 5.5 Beginning <strong>of</strong> the pulling-in with a barrel<br />

reamer ahead <strong>of</strong> the string <strong>of</strong> pipes