AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Replaceable Electrode TypeElectrode parts can be put into unit to facilitatereplacement or mounting at customer site.The optional dedicated tool (F9807SK) is required.Replaceable electrodes are available for thefollowing:<strong>AXF</strong> standard:UseGeneral-Purpose UseProcessConnectionWaferFlangeAvailableSize25 to 300 mm(1.0 to 12 in.)25 to 400 mm(1.0 to 16 in.)LiningPFA/PolyurethaneRubberElectrodeMaterialJIS SUS316L(AISI 316LSS/EN1.4404equivalent) ( * 1)T06.EPSReplacement model for earlier ADMAG or ADMAG AE:UseGeneral-Purpose UseProcessConnectionFlangeAvailableSize150 to 250 mm(6.0 to 10 in.)LiningPFA/PolyurethaneRubberElectrodeMaterialJIS SUS316L(AISI 316LSS/EN1.4404equivalent) ( * 1)T07.EPS*1: If any other electrode materials are required, pleasecontact Yokogawa office.Mounting/Shapes (Remote Flowtube):• Electrical Connection: ANSI 1/2 NPT femaleISO M20 1.5 femaleJIS G1/2 (PF1/2) female• Direction of Electrical Connection: The direction can bechanged even after delivery.Note: In case of submersible types, an optional codeDHC, and sizes of 1100 mm or larger, the directioncan not be changed after delivery.• Terminal Connection at Terminal Box: M4 size screwGrounding:Grounding resistance 100 Ω or less* In case of explosion proof type except TIIS, follow thedomestic electrical requirements as regulated in eachcountry.* In case of TIIS Flameproof type, refer to description of“HAZARDOUS AREA CLASSIFCATION”.Combined Converter:•A remote flowtube for sizes of up to 400 mm can becombined with the <strong>AXF</strong>A11 Converter or the <strong>AXF</strong>A14Converter. If a combined converter is changed from<strong>AXF</strong>A11 to <strong>AXF</strong>A14 or vice versa, a new meter factormust be adjusted by flow calibrations.• In case that size 250 mm (10 in.) or larger is used in lowconductivity or high concentration slurries, please usethe <strong>AXF</strong>A11 Converter.•A remote flowtube for sizes of 500 mm or larger can becombined with the <strong>AXF</strong>A11 Converter only.• Maximum Cable Length:Combination of <strong>AXF</strong> remote Flowtube and <strong>AXF</strong>A11:up to 200 m (660 ft)Combination of <strong>AXF</strong> remote Flowtube and <strong>AXF</strong>A14:up to 100 m (330 ft)10■ HAZARDOUS AREA CLASSIFICATIONFM:*<strong>AXF</strong>002C – <strong>AXF</strong>400CApplicable Standard:FM3600, FM3610, FM3615,FM3810, ANSI/NEMA 250(Integral Flowmeter)Explosion proof for Class I, Division 1, Groups A, B, C& D.Dust-ignition proof for Class II/III, Division1, Groups E,F & G.Intrinsically safe (electrodes) for Class I, Division 1,Groups A, B, C & D.“SEAL ALL CONDUITS WITHIN 18 INCHES”“WHEN INSTALLED IN DIV. 2, SEALS NOT REQUIRED”Electrode Circuit Um: 250 Vac/dcMaximum power supply voltage: 250 Vac/130 VdcExcitation Circuit: 140V maxEnclosure: NEMA 4XTemperature Code: T6Refer to following table;TemperatureCodeT6T5T4T3Maximum ProcessTemperature+70°C (+158°F)+85°C (+185°F)+120°C (+248°F)+130°C (+266°F)Minimum ProcessTemperature–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)Ambient Temp.: –40°C to +60°C (–40°F to +140°F)T27-1_1.EPS(Remote Flowtube)Explosion proof for Class I, Division 1, Groups A, B, C& D.Dust-ignition proof for Class II/III, Division1, Groups E,F & G.Intrinsically safe (electrodes) for Class I, Division 1,Groups A, B, C & D.“SEAL ALL CONDUITS WITHIN 18 INCHES”“WHEN INSTALLED IN DIV. 2, SEALS NOT REQUIRED”Electrode Circuit Um: 250 Vac/dcExcitation Circuit: 170V maxEnclosure: NEMA 4XTemperature Code: T6Refer to following table;TemperatureCodeT6T5T4T3Maximum ProcessTemperature+70°C (+158°F)+85°C (+185°F)+120°C (+248°F)+150°C (+302°F)Minimum ProcessTemperature–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)Ambient Temp.: –40°C to +60°C (–40°F to +140°F)Note: Installation shall be in accordance with themanufacturer’s instructions and National Electriccode, ANSI/NFPA-70.T28-1_1.EPSAll Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!