CSA:*<strong>AXF</strong>002C – <strong>AXF</strong>400CApplicable Standard:For CSA C22.2 Series;C22.2 No 0, C22.2 No 0.4, C22.2 No 0.5,C22.2 No 25, C22.2 No 30, C22.2 No 94,C22.2 No 157, C22.2 No 1010.1For CSA E79 Series;CAN/CSA-E79-0, CAN/CSA-E79-1,CAN/CSA-E79-7, CAN/CSA-E79-11,CAN/CSA-E79-18Certificate: 1481213(Integral Flowmeter)For CSA C22. 2 SeriesExplosion proof for Class I, Division 1, Groups A, B, C& D.Dust-ignition proof for Class II/III, Division 1, Groups E,F & G.Intrinsically safe (electrodes) for Class I, Division 1,Groups A, B, C & D.“SEAL ALL CONDUITS WITHIN 50 cm OF THEENCLOSURE”“WHEN INSTALLED IN DIV. 2, SEALS NOT REQUIRED”Electrode Circuit Um: 250 Vac/dcMaximum power supply voltage: 250 Vac/130 VdcExcitation Circuit: 140V maxEnclosure: Type 4XTemperature Code:TemperatureCodeT6T5T4T3Maximum ProcessTemperature+70°C (+158°F)+85°C (+185°F)+120°C (+248°F)+130°C (+266°F)Minimum ProcessTemperature–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)Ambient Temp.: –40°C to +60°C (–40°F to +140°F)For CSA E79 SeriesFlameproof for Zone 1, Ex dme[ia] IIC T6...T3Intrinsically safe (electrodes), Ex ia IIC T6...T3Electrode Circuit Um: 250 Vac/dcMaximum power supply voltage: 250 Vac/130 VdcExcitation Circuit: 140V maxEnclosure: IP66, IP67Temperature Code:T27-1.EPS12(Remote Flowtube)For CSA C22.2 SeriesExplosion proof for Class I, Division 1, Groups A, B, C& D.Dust-ignition proof for Class II/III, Division 1, Groups E,F & G.Intrinsically safe (electrodes) for Class I, Division 1,Groups A, B, C & D.“SEAL ALL CONDUITS WITHIN 50 cm OF THEENCLOSURE”“WHEN INSTALLED IN DIV. 2, SEALS NOT REQUIRED”Electrode Circuit Um: 250 Vac/dcExcitation Circuit: 170V maxEnclosure: Type 4XTemperature Code:TemperatureCodeT6T5T4T3Maximum ProcessTemperature+70°C (+158°F)+85°C (+185°F)+120°C (+248°F)+150°C (+302°F)Minimum ProcessTemperature–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)Ambient Temp.: –40°C to +60°C (–40°F to +140°F)For CSA E79 SeriesFlameproof for Zone 1, Ex dme[ia] IIC T6...T3Intrinsically safe (electrodes), Ex ia IIC T6...T3Electrode Circuit Um: 250 Vac/dcExcitation Circuit: 170V maxEnclosure: IP66, IP67Temperature Code:TemperatureCodeT6T5T4T3Maximum ProcessTemperature+70°C (+158°F)+85°C (+185°F)+120°C (+248°F)+150°C (+302°F)–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)T28-1.EPSMinimum ProcessTemperatureT28-1.EPSAmbient Temp.: –40°C to +60°C (–40°F to +140°F)TemperatureCodeMaximum ProcessTemperatureMinimum ProcessTemperatureT6T5+70°C (+158°F)+85°C (+185°F)–40°C (–40°F)–40°C (–40°F)T4 +120°C (+248°F) –40°C (–40°F)T3 +130°C (+266°F) –40°C (–40°F)Ambient Temp.: –40°C to +60°C (–40°F to +140°F)T27-1.EPSAll Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00
IECEx:*<strong>AXF</strong>002C – <strong>AXF</strong>400CApplicable Standard:IEC60079-0: 2004, IEC60079-1: 2003,IEC60079-7: 2001,IEC60079-11: 1999, IEC60079-18: 2004,IEC61241-0: 2004, IEC61241-1: 2004,IEC60529: 1999 + Edition 2.1: 2001Certificate: IECEx KEM 05.0018(Integral Flowmeter)IECEx Flameproof TypeEx demb[ia] IIC T6...T3Electrode Circuit Um: 250 Vac/dcMaximum power supply voltage: 250 Vac/130 VdcExcitation Circuit: 140V maxEnclosure: IP66, IP67Temperature Class:TemperatureClassT6T5T4T3Process Temperature–40°C to +70°C (–40°F to +158°F)–40°C to +85°C (–40°F to +185°F)–40°C to +120°C (–40°F to +248°F)–40°C to +130°C (–40°F to +266°F)T27-3.EPSAmbient Temp.:PFA Lining; –40˚C to +60˚C (–40˚F to +140˚F)Ceramics Lining; –15˚C to +60˚C (5˚F to +140˚F)IECEx Type of Protection “Dust”Ex tD A21 IP6x T95°C, T105°C, T120°C, T130°CElectrode Circuit Um: 250 Vac/dcMaximum power supply voltage: 250 Vac/130 VdcExcitation Circuit: 140V maxEnclosure: IP66, IP67Maximum surface temperature:(Remote Flowtube)IECEx Flameproof TypeEx demb[ia] IIC T6...T3Electrode Circuit Um: 250 Vac/dcExcitation Circuit: 170V maxEnclosure: IP66, IP67Temperature Class:TemperatureClassT6T5T4T3Process Temperature–40°C to +70°C (–40°F to +158°F)–40°C to +85°C (–40°F to +185°F)–40°C to +120°C (–40°F to +248°F)–40°C to +150°C (–40°F to +302°F)13T27-5.EPSAmbient Temp.:PFA Lining; –40˚C to +60˚C (–40˚F to +140˚F)Ceramics Lining; –15˚C to +60˚C (5˚F to +140˚F)IECEx Type of Protection “Dust”Ex tD A21 IP6x T95°C, T105°C, T120°C, T135°CElectrode Circuit Um: 250 Vac/dcExcitation Circuit: 170V maxEnclosure: IP66, IP67Maximum surface temperature:Maximum SurfaceTemperatureT95°C (+203°F)T105°C (+221°F)T120°C (+248°F)T135°C (+275°F)Process Temperature–40°C to +70°C (–40°F to +158°F)–40°C to +85°C (–40°F to +185°F)–40°C to +120°C (–40°F to +248°F)–40°C to +150°C (–40°F to +302°F)T27-6.EPSAmbient Temp.:PFA Lining; –40˚C to +60˚C (–40˚F to +140˚F)Ceramics Lining; –15˚C to +60˚C (5˚F to +140˚F)Maximum SurfaceTemperatureProcess TemperatureT95°C (+203°F)T105°C (+221°F)T120°C (+248°F)T130°C (+266°F)–40°C to +70°C (–40°F to +158°F)–40°C to +85°C (–40°F to +185°F)–40°C to +120°C (–40°F to +248°F)–40°C to +130°C (–40°F to +266°F)T27-4.EPSAmbient Temp.:PFA Lining; –40˚C to +60˚C (–40˚F to +140˚F)Ceramics Lining; –15˚C to +60˚C (5˚F to +140˚F)All Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00
- Page 1 and 2: GeneralSpecificationsGS 01E20D01-01
- Page 3 and 4: Functions “”How to Set Paramete
- Page 5 and 6: 5Size of AXF Flowtubes: AXF Standar
- Page 7 and 8: Flowtube Material:Size 2.5 mm (0.1
- Page 9 and 10: 9Gasket:Joints:UseLiningGeneral-Pur
- Page 11: CENELEC ATEX (KEMA):*AXF002C - AXF4
- Page 15 and 16: Polyurethane Rubber /Natural Soft R
- Page 17 and 18: ■ NORMAL OPERATING CONDITIONSAmbi
- Page 19 and 20: Fluid Temperature and Pressure:Note
- Page 21 and 22: Reasonable Figure for Thermal Shock
- Page 23 and 24: Size500 (20)600 (24)700 (28)800 (32
- Page 25 and 26: 25AXF STANDARD (Wafer /Union Joint
- Page 27 and 28: 27AXF STANDARD (Flange Type) Size 5
- Page 29 and 30: 29REPLACEMENT MODEL FOR EARLIER ADM
- Page 31 and 32: 31■ OPTIONAL SPECIFICATIONS FOR F
- Page 33 and 34: 33 Table of Optional Specifications
- Page 35 and 36: 35 Table of Optional Specifications
- Page 37 and 38: 37■ EXTERNAL DIMENSIONS AXF Stand
- Page 39 and 40: 39 AXF Standard, AXF015, Wafer Type
- Page 41 and 42: 41 AXF Standard, AXF002-AXF015, JIS
- Page 43 and 44: 43 AXF Standard, AXF065-AXF125, JIS
- Page 45 and 46: 45 AXF Standard, AXF250-AXF400, JIS
- Page 47 and 48: 47 AXF Standard, AXF015-AXF125, San
- Page 49 and 50: 49 Replacement model for Earlier AD
- Page 51 and 52: 51 Replacement model for Earlier AD
- Page 53 and 54: 53 AXF Standard, AXF11L-AXF13L, JIS
- Page 55 and 56: 55 Unless otherwise specified, diff