38 <strong>AXF</strong> Standard, <strong>AXF</strong>150-<strong>AXF</strong>300, Wafer Type, PFA /Polyurethane Rubber /Natural Soft Rubber /EPDMRubber Lining<strong>AXF</strong>150G<strong>AXF</strong>200W<strong>AXF</strong>250C<strong>AXF</strong>300*5DEFNP12NAUDG12*5: D, E, F; Integral Flowmeter,N, P; Remote FlowtubeA 1* No infra-red switches are furnishedfor Fieldbus communication type.Hi73(2.87) 49(1.93)Integral Flowmeter154(6.06)ModelSize codeSize150150(6)200200(8)250250(10)300300(12)Lining codeA,U A,U A,U A,UD,G D,G D,G D,GFace-to-facelengthRemote Outside dia.L *2øD200(7.87)202(7.95)250(9.84)252(9.92)300(11.81)310(12.20)350(13.78)358(14.09)Flowtube Inner diameter ofGrounding ring ødIntegral146.1(5.75) 193.6(7.62) 243.7(9.59) 294.7(11.60)Flowmeter Width*W202(7.95) 252(9.92) 310(12.20) 358(14.09)Height H1 243(9.57) 293(11.54) 354(13.94) 402(15.83)RemoteMax. Height Hr 367(14.45) 417(16.42) 478(18.82) 526(20.71)FlowtubeWeight kg (lb)* 414.5(32.0) 22.1(48.7) 39.0(86.0) 48.3(106.5)Integral Max. Height Hi 405(15.93) 455(17.89) 516(20.31) 564(22.20)FlowmeterWeight kg (lb) 16.2(35.7) 23.8(52.4) 40.7(89.7) 50.0(110.2)Hr70(2.76)H1Remote FlowtubeGround Terminal(M4)ø86(3.38)48(1.89)Unit : mm (approx. inch)Integral Flowmeter Remote Flowtube197(7.76)* 1 Ground Terminal(M4)66* 1 51.5 51.5 28(1.1)(2.6) (2.03) (2.03)111(4.37)L* 2W* 3*1: When indicator code N is selected, subtract 12 mm (0.47 inch)from the value in the figure.In case of explosion proof type with indicator, add 5 mm (0.2 inch) to it.*2: Depending on the selection of grounding ring code and optionalcode, add the following value to L (face-to-face length).Nominal Size: 150 to 200mmGrounding Ring Code S, L, H, V P, T NNone +0 +32(1.26) -2(0.08)OptionCode GA, GC, GD+10(0.39) +38(1.5) –(Special Gaskets)Nominal Size: 250 to 300mmGrounding Ring Code S, L, H, V P, T NOption Code is “None” +0 – -2(0.08)*3: When electrode structure 2 is selected, add the following value toW(width).Nominal size 150 200 250 300W +49(1.93) +50(1.97) +49(1.93) +53(2.09)*4: When submersible type or option code DHC is selected,waterproof glands and a 30m long cable are attached.Add 9.5kg(20.9lb) to the weight in the table. <strong>AXF</strong> Standard, <strong>AXF</strong>002-<strong>AXF</strong>010, Weld · Union Joint, Ceramics Liningø128(5.04)* In case of size250mm or 300mm,position of groundingring is differentfrom the figure to45-degree.øD(ød)F24.EPS<strong>AXF</strong>002G<strong>AXF</strong>005C<strong>AXF</strong>010*2DE 1WF 2 C E 1 N G U N 1N NRP*2: D, E, F; Integral Flowmeter,N, P; Remote FlowtubeHi49(1.93)73(2.87)Integral Flowmeter154(6.06)70(2.76)Remote FlowtubeGround Terminal(M4)ø86(3.38)48(1.89)H163.5(2.50)HrUnit : mm (approx. inch)Integral Flowmeter Remote FlowtubeGround Terminal(M4)197(7.76)* 166* 1 51.5 51.5 28(1.1)(2.6) (2.03) (2.03)111(4.37)ø128(5.04)3(0.12)* No infra-red switches are furnishedfor Fieldbus communication type.L4- ø6.2(0.24)72 (2.83)58 (2.28)Process connection GUW (Welding type) GUN/GUR (Union joint type)ModelRemoteflowtubeIntegral<strong>flowmeter</strong>RemoteflowtubeIntegral<strong>flowmeter</strong>Size codeSizeLining code0022.5(0.1)C0055(0.2)C01010(0.4)CFace-to-facelengthL140(5.51)Height H1144(5.67)Max. Height Hr268(10.55)Weight kg (lb)2.3(5.1)Max. Height Hi306(12.03)Weight kg (lb)4(8.8)0022.5(0.1)C0055(0.2)C01010(0.4)C130(5.12)144(5.67)268(10.55)2.3(5.1)306(12.03)4(8.8)*1: When indicator code N is selected, subtract 12 mm (0.47 inch)from the value in the figure.In case of explosion proof type with indicator, add 5 mm (0.2 inch) to it.All Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>orationøA4(0.16)Union joint11.5 (0.45)30(1.18)DøB øCSize A B C D2.5(0.1)5(0.2)22(0.87)22(0.87)22(0.87)22(0.87)8(0.31)8(0.31)8(0.31)8(0.31)18.5(0.73)18.5(0.73)18.5(0.73)18.5(0.73)R1/4NPT1/4R1/4NPT1/410(0.4)25(0.98)25(0.98)10(0.39) 22.5(0.89)10(0.39) 22.5(0.89)R3/8NPT3/8øA øB4(0.16)Size2.5(0.1)5(0.2)10(0.4)A22(0.87)22(0.87)25(0.98)Weld joint35(1.38)B8(0.31)8(0.31)10(0.39)10øC øD(0.39)C D14.3(0.56) 18.5(0.73)14.3(0.56) 18.5(0.73)17.8(0.70) 22.5(0.89)F25.EPSGS 01E20D01-01E May 10,2006-00
39 <strong>AXF</strong> Standard, <strong>AXF</strong>015, Wafer Type, Ceramics Lining<strong>AXF</strong>015 G C*3DE 1F 2 C E 1 A 1N NP*3: D, E, F; Integral Flowmeter,N, P; Remote Flowtube49(1.93)Hi73(2.87)Integral Flowmeter154(6.06)HrRemote FlowtubeGround Terminal(M4)ø86(3.38)48 (1.89)70(2.76)H163.5(2.50)3(0.12)DUnit : mm (approx. inch)Integral Flowmeter Remote Flowtube197(7.76)* 1 Ground Terminal(M4)66* 1 51.5 51.5 28(1.1)(2.6) (2.03) (2.03)111(4.37)ø128(5.04)(ød)* No infra-red switches are furnishedfor Fieldbus communication type.L* 24- ø6.2(0.24)7258(2.83)(2.28)ModelRemoteflowtubeIntegral<strong>flowmeter</strong>HeightSize codeSizeLining codeFace-to-facelengthOutside dia.Inner diameter ofGrounding ringL *2DødH101515(0.5)C85(3.35)44(1.73)15(0.59)144(5.67)*1: When indicator code N is selected, subtract 12 mm(0.47 inch) from the value in the figure.In case of explosion proof type with indicator, add 5 mm(0.2 inch) to it.*2: Depending on the selection of grounding ring code andoptional code, add the following value to L (face-to-facelength).Grounding Ring Code S, L, H, V P, T NL(Face-to-face length) +0 +22(087) -6(0.24)RemoteflowtubeMax. HeightWeight kg (lb)Hr268(10.55)2.3(5.1)Integral<strong>flowmeter</strong>Max. HeightWeight kg (lb)Hi306(12.03)4(8.8)F26.EPS <strong>AXF</strong> Standard, <strong>AXF</strong>025-<strong>AXF</strong>100, Wafer Type, Ceramics Lining<strong>AXF</strong>025<strong>AXF</strong>040G<strong>AXF</strong>050C<strong>AXF</strong>080<strong>AXF</strong>100*3DEF12 C E 1 A 1N NP*3: D, E, F; Integral Flowmeter,N, P; Remote Flowtube49(1.93)Hi73(2.87)Integral Flowmeter Remote FlowtubeGround Terminal(M4)154(6.06)ø86(3.38)48(1.89)Hr70(2.76)Unit : mm (approx. inch)Integral Flowmeter Remote Flowtube66* 1(2.6)Ground Terminal(M4)197(7.76)* 1H151.5 51.5(2.03) (2.03)28(1.1)111(4.37)ø128(5.04)øD(ød)Size codeModel SizeLining codeFace-to-facelength L *2RemoteFlowtubeOutside dia. øDIntegral Inner diameter ofFlowmeter Grounding ring ødRemoteFlowtubeHeightMax. HeightWeight kg (lb)H1Hr025 04025(1) 40(1.5)C C93(3.66) 106(4.17)67.5(2.66) 86(3.39)27(1.06) 40(1.57)92(3.62) 111(4.37)216(8.50) 235(9.25)2.3(5.1) 3.2(7.0)* No infra-red switches are furnished L* 2for Fieldbus communication type.050 080 100 *1: When indicator code N is selected, subtract 12 mm (0.47inch) from the value in the figure.50(2) 80(3) 100(4)In case of explosion proof type with indicator, add 5 mm(0.2 inch) to it.C C C *2: Depending on the selection of grounding ring code andoptional code, add the following value to L (face-to-face120(4.72) 160(6.30) 180(7.09) length).99(3.90) 129(5.08) 155(6.10)Grounding Ring Code S, L, H, V P, T NL(Face-to-face length) +0 +22(0.87) -6(0.24)52(2.05) 81(3.19) 98(3.86)129(5.08) 159(6.26) 184(7.24)253(9.96) 283(11.14) 308(12.13)4.1(9.0) 6.8(15.0) 9.6(21.1)IntegralMax. Height HiFlowmeterWeight kg (lb)254(9.98) 273(10.73) 291(11.44) 321(12.64) 346(13.62)4.0(8.8) 4.9(10.8) 5.8(12.7) 8.5(18.8) 11.3(24.9)F27.EPSAll Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00
- Page 1 and 2: GeneralSpecificationsGS 01E20D01-01
- Page 3 and 4: Functions “”How to Set Paramete
- Page 5 and 6: 5Size of AXF Flowtubes: AXF Standar
- Page 7 and 8: Flowtube Material:Size 2.5 mm (0.1
- Page 9 and 10: 9Gasket:Joints:UseLiningGeneral-Pur
- Page 11 and 12: CENELEC ATEX (KEMA):*AXF002C - AXF4
- Page 13 and 14: IECEx:*AXF002C - AXF400CApplicable
- Page 15 and 16: Polyurethane Rubber /Natural Soft R
- Page 17 and 18: ■ NORMAL OPERATING CONDITIONSAmbi
- Page 19 and 20: Fluid Temperature and Pressure:Note
- Page 21 and 22: Reasonable Figure for Thermal Shock
- Page 23 and 24: Size500 (20)600 (24)700 (28)800 (32
- Page 25 and 26: 25AXF STANDARD (Wafer /Union Joint
- Page 27 and 28: 27AXF STANDARD (Flange Type) Size 5
- Page 29 and 30: 29REPLACEMENT MODEL FOR EARLIER ADM
- Page 31 and 32: 31■ OPTIONAL SPECIFICATIONS FOR F
- Page 33 and 34: 33 Table of Optional Specifications
- Page 35 and 36: 35 Table of Optional Specifications
- Page 37: 37■ EXTERNAL DIMENSIONS AXF Stand
- Page 41 and 42: 41 AXF Standard, AXF002-AXF015, JIS
- Page 43 and 44: 43 AXF Standard, AXF065-AXF125, JIS
- Page 45 and 46: 45 AXF Standard, AXF250-AXF400, JIS
- Page 47 and 48: 47 AXF Standard, AXF015-AXF125, San
- Page 49 and 50: 49 Replacement model for Earlier AD
- Page 51 and 52: 51 Replacement model for Earlier AD
- Page 53 and 54: 53 AXF Standard, AXF11L-AXF13L, JIS
- Page 55 and 56: 55 Unless otherwise specified, diff