11.07.2015 Views

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

39 <strong>AXF</strong> Standard, <strong>AXF</strong>015, Wafer Type, Ceramics Lining<strong>AXF</strong>015 G C*3DE 1F 2 C E 1 A 1N NP*3: D, E, F; Integral Flowmeter,N, P; Remote Flowtube49(1.93)Hi73(2.87)Integral Flowmeter154(6.06)HrRemote FlowtubeGround Terminal(M4)ø86(3.38)48 (1.89)70(2.76)H163.5(2.50)3(0.12)DUnit : mm (approx. inch)Integral Flowmeter Remote Flowtube197(7.76)* 1 Ground Terminal(M4)66* 1 51.5 51.5 28(1.1)(2.6) (2.03) (2.03)111(4.37)ø128(5.04)(ød)* No infra-red switches are furnishedfor Fieldbus communication type.L* 24- ø6.2(0.24)7258(2.83)(2.28)ModelRemoteflowtubeIntegral<strong>flowmeter</strong>HeightSize codeSizeLining codeFace-to-facelengthOutside dia.Inner diameter ofGrounding ringL *2DødH101515(0.5)C85(3.35)44(1.73)15(0.59)144(5.67)*1: When indicator code N is selected, subtract 12 mm(0.47 inch) from the value in the figure.In case of explosion proof type with indicator, add 5 mm(0.2 inch) to it.*2: Depending on the selection of grounding ring code andoptional code, add the following value to L (face-to-facelength).Grounding Ring Code S, L, H, V P, T NL(Face-to-face length) +0 +22(087) -6(0.24)RemoteflowtubeMax. HeightWeight kg (lb)Hr268(10.55)2.3(5.1)Integral<strong>flowmeter</strong>Max. HeightWeight kg (lb)Hi306(12.03)4(8.8)F26.EPS <strong>AXF</strong> Standard, <strong>AXF</strong>025-<strong>AXF</strong>100, Wafer Type, Ceramics Lining<strong>AXF</strong>025<strong>AXF</strong>040G<strong>AXF</strong>050C<strong>AXF</strong>080<strong>AXF</strong>100*3DEF12 C E 1 A 1N NP*3: D, E, F; Integral Flowmeter,N, P; Remote Flowtube49(1.93)Hi73(2.87)Integral Flowmeter Remote FlowtubeGround Terminal(M4)154(6.06)ø86(3.38)48(1.89)Hr70(2.76)Unit : mm (approx. inch)Integral Flowmeter Remote Flowtube66* 1(2.6)Ground Terminal(M4)197(7.76)* 1H151.5 51.5(2.03) (2.03)28(1.1)111(4.37)ø128(5.04)øD(ød)Size codeModel SizeLining codeFace-to-facelength L *2RemoteFlowtubeOutside dia. øDIntegral Inner diameter ofFlowmeter Grounding ring ødRemoteFlowtubeHeightMax. HeightWeight kg (lb)H1Hr025 04025(1) 40(1.5)C C93(3.66) 106(4.17)67.5(2.66) 86(3.39)27(1.06) 40(1.57)92(3.62) 111(4.37)216(8.50) 235(9.25)2.3(5.1) 3.2(7.0)* No infra-red switches are furnished L* 2for Fieldbus communication type.050 080 100 *1: When indicator code N is selected, subtract 12 mm (0.47inch) from the value in the figure.50(2) 80(3) 100(4)In case of explosion proof type with indicator, add 5 mm(0.2 inch) to it.C C C *2: Depending on the selection of grounding ring code andoptional code, add the following value to L (face-to-face120(4.72) 160(6.30) 180(7.09) length).99(3.90) 129(5.08) 155(6.10)Grounding Ring Code S, L, H, V P, T NL(Face-to-face length) +0 +22(0.87) -6(0.24)52(2.05) 81(3.19) 98(3.86)129(5.08) 159(6.26) 184(7.24)253(9.96) 283(11.14) 308(12.13)4.1(9.0) 6.8(15.0) 9.6(21.1)IntegralMax. Height HiFlowmeterWeight kg (lb)254(9.98) 273(10.73) 291(11.44) 321(12.64) 346(13.62)4.0(8.8) 4.9(10.8) 5.8(12.7) 8.5(18.8) 11.3(24.9)F27.EPSAll Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!