11.07.2015 Views

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

43 <strong>AXF</strong> Standard, <strong>AXF</strong>065-<strong>AXF</strong>125, JIS/ANSI/DIN Flange Type, PFA /Polyurethane Rubber /Natural SoftRubber /EPDM Rubber LiningIntegral Flowmeter154(6.06)Remote FlowtubeGround Terminal(M4)ø86 (3.38)48 (1.89)Integral FlowmeterGround Terminal(M4)197(7.76)* 166* 1 51.5 51.5(2.6) (2.03) (2.03)Unit : mm (approx. inch)28(1.1)Remote Flowtube111(4.37)<strong>AXF</strong>065G<strong>AXF</strong>080W<strong>AXF</strong>100C<strong>AXF</strong>125*4DEFNP12NAUDG12*4: D, E, F; Integral Flowmeter,N, P; Remote FlowtubeBBBBCCCCADJGADJG21211Hi73(2.87) 49(1.93)HrH1(H2) 70(2.76)t * 2ø128(5.04)N-øhøDøC(ød)* No infra-red switches are furnishedfor Fieldbus communication type.L* 2θ°Process Connection BJ1/CJ1(JIS10K) BJ2/CJ2(JIS20K) BG1/CG1(JIS F12) BA1/CA1(ANSI Class 150) BA2/CA2(ANSI Class 300)Size code 065 080 100 125 065 080 100 125 080 100 125 065 080 100 125 065 080 100 125Model65 80 100 125 65 80 100 125 80 100 125 65 80 100 125 65 80 100 125Size (2.5) (3) (4) (5) (2.5) (3) (4) (5) (3) (4) (5) (2.5) (3) (4) (5) (2.5) (3) (4) (5)A,ULining codeA,U A,U A,U A,U A,U A,U A,U A,U A,U A,U A,U A,U A,U A,U A,U A,U A,U A,U0Face-to-face length L -3*2Outside dia. øDThickness * t2Inner diameter ofRemote Grounding ring ødflowtube Pitch circle dia. øCBolt hole interval ˚IntegralHole dia. øh<strong>flowmeter</strong>Number of holes NHeight H1Height H2Max. Height HrRemoteflowtubeIntegral<strong>flowmeter</strong>Weight kg (lb)* 3Max. Height HiWeight kg (lb)D,G200(7.87)175(6.89)22(0.87)66(2.60)140(5.51)4519(0.75)4176(6.93)89(3.50)300(11.81)9.0(19.8)338(13.31)10.7(23.5)D,G200(7.87)185(7.28)22(0.87)77(3.03)150(5.91)22.519(0.75)8187(7.36)95(3.74)311(12.24)9.6(21.2)349(13.74)11.3(25.0)D,G250(9.84)210(8.27)22(0.87)102(4.02)175(6.89)22.519(0.75)8211(8.30)106(4.16)335(13.18)12.4(27.3)372(14.65)14.1(31.0)D,G250(9.84)250(9.84)24(0.94)128(5.04)210(8.27)22.523(0.91)8245(9.65)120(4.73)369(14.53)17.4(38.3)407(16.01)19.1(42.1)D,G200(7.87)175(6.89)24(0.94)66(2.60)140(5.51)22.519(0.75)8176(6.93)89(3.50)300(11.81)9.3(20.5)338(13.31)11.0(24.3)D,G200(7.87)200(7.87)26(1.02)77(3.03)160(6.30)22.523(0.91)8195(7.68)95(3.74)319(12.56)12.4(27.3)357(14.06)14.1(31.0)D,G250(9.84)225(8.86)28(1.10)102(4.02)185(7.28)22.523(0.91)8218(8.59)106(4.16)342(13.47)16.9(37.3)380(14.95)18.6(41.0)D,G250(9.84)270(10.63)30(1.18)128(5.04)225(8.86)22.525(0.98)8255(10.04)120(4.73)379(14.92)24.7(54.5)417(16.40)26.4(58.3)D,G200(7.87)211(8.31)22(0.87)77(3.03)168(6.61)4519(0.75)4200(7.87)95(3.74)324(12.76)12.2(26.9)362(14.25)13.9(30.7)D,G250(9.84)238(9.37)22(0.87)102(4.02)195(7.68)4519(0.75)4225(8.85)106(4.16)349(13.73)15.5(34.2)386(15.21)17.2(37.8)D,G250(9.84)263(10.35)24(0.94)128(5.04)220(8.66)3019(0.75)6252(9.90)120(4.73)376(14.79)19.5(43.1)413(16.26)21.2(46.8)D,G200(7.87)177.8(7.00)26.4(1.04)66(2.60)139.7(5.50)4519.1(0.75)4177(6.97)89(3.50)301(11.85)10.8(23.7)339(13.35)12.5(27.5)D,G200(7.87)190.5(7.50)27.9(1.10)77(3.03)152.4(6.00)4519.1(0.75)4190(7.48)95(3.74)314(12.36)12.9(28.5)352(13.86)14.6(32.2)D,G250(9.84)228.6(9.00)27.9(1.10)102(4.02)190.5(7.50)22.519.1(0.75)8220(8.66)106(4.16)344(13.54)17.7(39.1)382(15.02)19.4(42.8)D,G250(9.84)254.0(10.00)27.9(1.10)128(5.04)215.9(8.50)22.522.4(0.88)8247(9.72)120(4.72)371(14.61)20.8(45.9)409(16.08)22.5(49.6)D,G200(7.87)190.5(7.50)29.4(1.16)66(2.60)149.4(5.88)22.522.4(0.88)8184(7.24)89(3.50)308(12.13)12.6(27.7)346(13.62)14.3(31.4)D,G200(7.87)209.6(8.25)32.4(1.28)77(3.03)168.1(6.62)22.522.4(0.88)8200(7.87)95(3.74)324(12.76)16.6(36.6)362(14.25)18.3(40.4)D,G250(9.84)254.0(10.00)35.8(1.41)102(4.02)200.2(7.88)22.522.4(0.88)8233(9.16)106(4.16)357(14.04)26.8(59.1)394(15.52)28.5(62.8)D,G250(9.84)279.4(11.00)39.1(1.54)128(5.04)235.0(9.25)22.522.4(0.88)8260(10.22)120(4.72)384(15.11)34.9(76.9)421(16.58)36.6(80.7)06565(2.5)A,UD,G200(7.87)185(7.28)22(0.87)66(2.60)145(5.71)4518(0.71)4181(7.13)89(3.50)305(12.01)9.8(21.6)343(13.50)11.5(25.4)BD2/CD2(DIN PN16)*1: When indicator code N is selected, subtract 12 mm (0.47 inch) from the value in the figure.In case of explosion proof type with indicator, add 5 mm (0.2 inch) to it.*2: Depending on the selection of grounding ring code and optional code, add the following value to “L” (face-to-face length) and “t” (thickness offlange).L t L t L tGrounding Ring Code S, L, H, V P, T NNone +0 +0 +26(1.02) +13(0.51) -2(0.08) -1(0.04)OptionCode GA, GC, GD +8(0.31) +4(0.16) +30(1.18) +15(0.59) – –(Special Gaskets)08080(3)A,UD,G200(7.87)200(7.87)24(0.94)77(3.03)160(6.30)22.518(0.71)8195(7.68)95(3.74)319(12.56)11.9(26.2)357(14.06)13.6(29.9)100100(4)A,UD,G250(9.84)220(8.66)24(0.94)102(4.02)180(7.09)22.518(0.71)8216(8.49)106(4.16)340(13.37)14.5(32.0)377(14.85)16.2(35.7)125125(5)A,UD,G250(9.84)250(9.84)26(1.02)128(5.04)210(8.27)22.518(0.71)8245(9.65)120(4.72)369(14.53)19.3(42.5)407(16.00)21.0(46.2)*3: When submersible type or option code DHC is selected, waterproof glands and a 30m long cable are attached.Add 9.5kg(20.9lb) to the weight in the table.F31.EPSAll Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!