11.07.2015 Views

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

41 <strong>AXF</strong> Standard, <strong>AXF</strong>002-<strong>AXF</strong>015, JIS/ANSI/DIN Flange Type, PFA LininigIntegral FlowmeterRemote FlowtubeIntegral FlowmeterUnit : mm (approx. inch)Remote Flowtube<strong>AXF</strong>002G<strong>AXF</strong>005W<strong>AXF</strong>010C<strong>AXF</strong>015*4DE 1F 2N NPA 1*4: D, E, F; Integral Flowmeter,N, P; Remote FlowtubeBBBBBDDDJJAADJJD12124124149(1.93)Hi73(2.87)154(6.06)HrH170(2.76)(H2)60.5(2.38)Ground Terminal(M4)ø86(3.38)48 (1.89)t * 2Ground Terminal(M4)197(7.76)* 166* 1 51.5 51.5 28(1.1)(2.6) (2.03) (2.03)ø128(5.04)111(4.37)N-øhøDøC(ød)* No infra-red switches are furnishedfor Fieldbus communication type.L* 2θ°ModelRemoteFlowtubeProcess ConnectionSize codeSizeLining code0Face-to-face length L -3*2Outside dia. øDThickness t * 2Inner diameter ofGrounding ring ødPitch circle dia. øCθ˚Bolt hole intervalIntegralFlowmeterHole dia. øhNumber of holes NHeight H1Height H2Remote Max. Height HrFlowtube Weight kg (lb)* 3IntegralFlowmeterMax. Height HiWeight kg (lb)0022.5(0.1)ABJ1(JIS10K)0055(0.2)A150(5.91)01010(0.4)A95(3.74)18 to 22(0.71 to 0.87)15(0.59)70(2.76)4515(0.59)4141(5.54)80(3.15)265(10.43)3.4(7.5)01515(0.5)0022.5(0.1)ABJ2(JIS20K)*1: When indicator code N is selected, subtract 12 mm (0.47 inch) from the value in the figure.In case of explosion proof type with indicator, add 5 mm (0.2 inch) to it.*2: Depending on the selection of grounding ring code and optional code, add the following value to “L” (face-to-face length) and “t” (thicknessof flange).L t L t L tGrounding Ring Code S, L, H, V P, T NNone +0 +0 +26(1.02) +13(0.51) -2(0.08) -1(0.04)OptionCode GA, GC, GD +8(0.31) +4(0.16) +30(1.18) +15(0.59) – –(Special Gaskets)0055(0.2)A01010(0.4)AA200(7.87) 150(5.91)16(0.63)3.5(7.7)303(11.91)5.1(11.2) 5.2(11.5)01515(0.5)A200(7.87)95(3.74)20 to 24 18(0.79 to 0.94) (0.71)15(0.59)70(2.76)4515(0.59)4141(5.54)80(3.15)265(10.43)3.6(7.9) 3.7(8.2)303(11.91)5.3(11.7) 5.4(11.9)BA1(ANSI Class 150) BA2(ANSI Class 300) BD4(DIN PN40)005 010 0155 10 15(0.2) (0.4) (0.5)A A A200150(5.91) (7.87)88.9(3.50)*3: When submersible type or option code DHC is selected, waterproof glands and a 30m long cable are attached.Add 9.5kg(20.9lb) to the weight in the table.0022.5(0.1)A17 to 22 15.2(0.67 to 0.87) (0.60)15(0.59)60.5(2.38)4515.7(0.62)4141(5.54)80(3.15)265(10.43)3.2(7.1) 3.3(7.3)303(11.91)4.9(10.8) 5.0(11.0)0022.5(0.1)A0055(0.2)A150(5.91)01010(0.4)A95.3(3.75)20 to 25(0.79 to 0.98)15(0.59)66.5(2.62)4515.7(0.62)4141(5.54)80(3.15)265(10.43)3.6(7.9)01515(0.5)A200(7.87)18.2(0.72)3.7(8.2)303(11.91)5.3(11.7) 5.4(11.9)0022.5(0.1)A0055(0.2)A150(5.91)01010(0.4)A95(3.74)21 to 25(0.83 to 0.98)01515(0.5)A200(7.87)20(0.79)15(0.59)65(2.56)4514(0.55)4141(5.54)80(3.15)265(10.43)3.8(8.4) 3.9(8.6)303(11.91)5.5(12.1) 5.6(12.4)DJ1(JIS10K) DJ2(JIS20K) DD4(DIN PN40)0022.5(0.1)A0055(0.2)A01010(0.4)A150(5.91)90(3.54)18 to 22(0.71 to 0.87)12(0.47)65(2.56)4515(0.59)4141(5.54)80(3.15)265(10.43)3.3(7.3)303(11.91)0022.5(0.1)A0055(0.2)A01010(0.4)A150(5.91)90(3.54)20 to 24(0.79 to 0.94)12(0.47)65(2.56)4515(0.59)4141(5.54)80(3.15)265(10.43)3.4(7.5)303(11.91)0022.5(0.1)A0055(0.2)A01010(0.4)A150(5.91)90(3.54)21 to 25(0.83 to 0.98)12(0.47)60(2.36)4514(0.55)4141(5.54)80(3.15)265(10.43)3.6(7.9)303(11.91)5.0(11.0) 5.1(11.2) 5.3(11.7)F29.EPSAll Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!