11.07.2015 Views

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

37■ EXTERNAL DIMENSIONS <strong>AXF</strong> Standard, <strong>AXF</strong>002-<strong>AXF</strong>015, Wafer Type, PFA Lining<strong>AXF</strong>002G<strong>AXF</strong>005W<strong>AXF</strong>010C<strong>AXF</strong>015*4DEF12 A 1 A 1N NP*4: D, E, F; Integral Flowmeter,N, P; Remote Flowtube49(1.93)Hi73(2.87)Integral Flowmeter154(6.06)HrRemote FlowtubeGround Terminal(M4)ø86(3.38)48 (1.89)70(2.76)H163.5(2.50)3(0.12)DUnit : mm (approx. inch)Integral Flowmeter Remote Flowtube197(7.76)* 1 Ground Terminal(M4)66* 1 51.5 51.5 28(1.1)(2.6) (2.03) (2.03)111(4.37)ø128(5.04)(ød)* No infra-red switches are furnishedfor Fieldbus communication type.L* 24- ø6.2(0.24)7258(2.83)(2.28)ModelRemoteflowtubeIntegral<strong>flowmeter</strong>RemoteflowtubeHeightSize codeSizeLining codeFace-to-facelengthOutside dia.Inner diameter ofGrounding ringMax. HeightWeight kg (lb)* 3L *2DødH1Hr0022.5(0.1)A005 0105(0.2) 10(0.4)A A81(3.19)44(1.73)15(0.59)144(5.67)268(10.55)2.4(5.3)01515(0.5)A*1: When indicator code N is selected, subtract 12 mm (0.47 inch)from the value in the figure.In case of explosion proof type with indicator, add 5 mm (0.2 inch) to it.*2: Depending on the selection of grounding ring code and optionalcode, add the following value to L (face-to-face length).Grounding Ring Code S, L, H, V P, T NNone +0 +26(1.02) -2(0.08)OptionCodeGA, GC, GD(Special Gaskets)+6(0.24) +28(1.10) –*3: When submersible type or option code DHC is selected,waterproof glands and a 30m long cable are attached.Add 9.5kg(20.9lb) to the weight in the table.Integral Max. Height Hi<strong>flowmeter</strong>Weight kg (lb)306(12.03)4.1(9.0)F22.EPS <strong>AXF</strong> Standard, <strong>AXF</strong>025-<strong>AXF</strong>125, Wafer Type, PFA /Polyurethane Rubber /Natural Soft Rubber /EPDMRubber LiningUnit : mm (approx. inch)<strong>AXF</strong>025<strong>AXF</strong>032<strong>AXF</strong>040G<strong>AXF</strong>050W<strong>AXF</strong>065C<strong>AXF</strong>080<strong>AXF</strong>100<strong>AXF</strong>125*5DEFNP12NAUDG12A 1*5: D, E, F; Integral Flowmeter,N, P; Remote Flowtube49(1.93)Hi73(2.87)Integral <strong>flowmeter</strong> Remote Flowtube Integral <strong>flowmeter</strong> Remote FlowtubeGround Terminal(M4)154(6.06) ø86(3.38)48(1.89)Hr70(2.76)Hr66* 1(2.6)197(7.76)* 151.5 51.5(2.03) (2.03)Ground Terminal(M4)28(1.1)111(4.37)ø128(5.04)øD(ød)ModelSize codeSizeLining codeFace-to-facelength L *2Remote Outside dia. øDFlowtubeInner diameter ofGrounding ring ødIntegralFlowmeter Width W* 3Height H1Remote Max. Height HrFlowtubeWeight kg (lb)* 4Integral Max. Height HiFlowmeterWeight kg (lb)* No infra-red switches are furnished L* 2W* 3for Fieldbus communication type.02525(1)03232(1.25)04040(1.5)05050(2)06565(2.5)08080(3)100100(4)125125(5)*1: When indicator code N is selected, subtract 12mm (0.47 inch) from the value in the figure.In case of explosion proof type with indicator, add5 mm (0.2 inch) to it.A,U A,U A,UA,U A,U A,U A,U A,U*2: Depending on the selection of grounding ringD,G D,G D,G D,G D,Gcode and optional code, add the following value to60(2.36) 70(2.76) 70(2.76) 80(3.15) 100(3.94) 120(4.72) 150(5.91) 200(7.87) L (face-to-face length).67.5(2.66) 73(2.87) 86(3.39) 99(3.90) 117(4.61) 129(5.08) 155(6.10) 183(7.20)Grounding Ring Code S, L, H, V P, T NOptionNone+0 +26(1.02) -2(0.08)28(1.10) 34(1.34) 41(1.61) 53(2.09) 66(2.60) 77(3.03) 102(4.02) 128(5.04) Code(Special Gaskets)GA, GC, GD+8(0.31) +30(1.18) –67.5(2.66) 73(2.87) 86(3.39) 99(3.90) 117(4.61) 129(5.08) 155(6.10) 183(7.20) *3: When electrode structure 2 is selected, add thefollowing value to W (width).92(3.62) 98(3.86) 111(4.37) 129(5.08) 147(5.79) 157(6.18) 183(7.20) 212(8.35)216(8.50) 222(8.74) 235(9.25) 253(9.96) 271(10.67) 281(11.06) 307(12.09) 336(13.23)NominalSize25 32, 40, 50 65, 80 100 125W +52.5(2.07) +52(2.05) +49(1.93) +48(1.89) +47(1.85)1.9(4.1) 2.0(4.5) 2.2(4.9) 2.7(5.8) 3.4(7.6) 4.1(9.1) 5.6(12.3) 9.3(20.4) *4: When submersible type or option code DHC isselected, waterproof glands and a 30m long cable254(9.98) 260(10.24) 273(10.73) 291(11.44) 309(12.17) 319(12.54) 345(13.56) 374(14.70) are attached.Add 9.5kg(20.9lb) to the weight in the table.3.6(7.8) 3.7(8.2) 3.9(8.7) 4.4(9.6) 5.1(11.3) 5.8(12.9) 7.3(16.0) 11.0(24.2)F23.EPSAll Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!