11.07.2015 Views

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Polyurethane Rubber /Natural Soft Rubber /EPDM Rubber Lining:Size mm (in.)25 (1.0)to400 (16)500 (20)to1000 (40)1100 (44)to2000 (80)2200 (88)to2600 (104)Flow VelocityV m/s (ft/s)Standard Accuracy(Calibration code B)V 0.3 (1.0) 1.0 mm/s0.3 V 10(1.0) (33)0.35% of RateV 0.3 (1.0) 1.75 mm/s0.3 V 1(1.0) (3.3)0.25% of Rate 1 mm/s1 V 10(3.3) (33)0.35% of RateV 0.3 (1.0) 2.2 mm/s0.3 V 1(1.0) (3.3)0.4% of Rate 1 mm/s1 V 10(3.3) (33)0.5% of RateV 1 (3.3) 8.5 mm/s1 V 10(3.3) (33)0.85% of RateT09.EPSEnhanced dual frequency excitation(Option code HF2) :Standard accuracy 1 mm/ sSize 25 mm (1.0 in.) to 400 mm (16 in.)% of Rate1.21.00.8Pulse 0.6OutputAccuracy 0.40.350.20High Standard grade Accuracy0 1 2 6 8 10V[m/s]F14.EPSSize 500 mm (20 in.) to 1000 mm (40 in.)% of Rate1.21.00.8Pulse 0.6OutputAccuracy 0.40.350.20High Standard grade Accuracy0 1 2 6 8 10V[m/s]F16-1.EPSSize 1100 mm (44 in.) to 2000 mm (80 in.)% of Rate1.21.00.8Pulse 0.6Output 0.5Accuracy 0.40.20High Standard grade Accuracy0 1 2 6 8 10V[m/s]F16-2.EPSSize 2200 mm (88 in.) to 2600 mm (104 in.)% of Rate2.42.01.6Pulse 1.2OutputAccuracy 0.850.80.40High Standard grade Accuracy150 1 2 6 8 10V[m/s]F16-3.EPSCurrent Output “”: Pulse output accuracy plus0.05% of SpanRepeatability:0.1% of Rate (V 1 m/s (3.3 ft/s))0.05% of Rate 0.5 mm/s (V < 1 m/s (3.3 ft/s))Maximum Power Consumption:Integral Flowmeter: 12WRemote Flowtube: Combined with <strong>AXF</strong>A11: 20WCombined with <strong>AXF</strong>A14: 12WInsulation Resistance (*1):Integral Flowmeter:Between power supply terminals and groundterminalm : 100MΩ at 500V DCBetween power supply terminals and input /outputterminals : 100MΩ at 500V DCBetween ground terminal and input/outputterminals : 20MΩ at 100V DCBetween input/output terminals : 20MΩ at 100V DCRemote Flowtube:Between excitation current terminal and signal /common terminals : 100MΩ at 500V DCBetween signal terminals : 100MΩ at 500V DCBetween signal terminals and common terminal (C) :100MΩ at 500V DCWithstand Voltage (*1):Integral FlowmeterBetween power supply terminals and ground terminal :1390V AC for 2 secondsBetween power supply terminals and input/outputterminals : 1390V AC for 2 secondsRemote Flowtube (option code JF3, KF2, CF1, and SF2)Between excitation current terminal and groundterminal : 1500V AC for 1 minuteBetween signal terminals and ground terminal :1500V AC for 1 minuteBetween signal terminals and excitation currentterminal : 2000V AC for 1 minuteRemote Flowtube (option code FF1)Between signal terminals and ground terminal : 500VAC for 1 minute or 600V AC for 1 secondBetween signal terminals and excitation currentterminal : 2000V AC for 1 minute or 2400V AC for1 second.All Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!