Replaceable Electrode TypeElectrode parts can be put into unit to facilitatereplacement or mounting at customer site.The optional dedicated tool (F9807SK) is required.Replaceable electrodes are available for thefollowing:<strong>AXF</strong> standard:UseGeneral-Purpose UseProcessConnectionWaferFlangeAvailableSize25 to 300 mm(1.0 to 12 in.)25 to 400 mm(1.0 to 16 in.)LiningPFA/PolyurethaneRubberElectrodeMaterialJIS SUS316L(AISI 316LSS/EN1.4404equivalent) ( * 1)T06.EPSReplacement model for earlier ADMAG or ADMAG AE:UseGeneral-Purpose UseProcessConnectionFlangeAvailableSize150 to 250 mm(6.0 to 10 in.)LiningPFA/PolyurethaneRubberElectrodeMaterialJIS SUS316L(AISI 316LSS/EN1.4404equivalent) ( * 1)T07.EPS*1: If any other electrode materials are required, pleasecontact Yokogawa office.Mounting/Shapes (Remote Flowtube):• Electrical Connection: ANSI 1/2 NPT femaleISO M20 1.5 femaleJIS G1/2 (PF1/2) female• Direction of Electrical Connection: The direction can bechanged even after delivery.Note: In case of submersible types, an optional codeDHC, and sizes of 1100 mm or larger, the directioncan not be changed after delivery.• Terminal Connection at Terminal Box: M4 size screwGrounding:Grounding resistance 100 Ω or less* In case of explosion proof type except TIIS, follow thedomestic electrical requirements as regulated in eachcountry.* In case of TIIS Flameproof type, refer to description of“HAZARDOUS AREA CLASSIFCATION”.Combined Converter:•A remote flowtube for sizes of up to 400 mm can becombined with the <strong>AXF</strong>A11 Converter or the <strong>AXF</strong>A14Converter. If a combined converter is changed from<strong>AXF</strong>A11 to <strong>AXF</strong>A14 or vice versa, a new meter factormust be adjusted by flow calibrations.• In case that size 250 mm (10 in.) or larger is used in lowconductivity or high concentration slurries, please usethe <strong>AXF</strong>A11 Converter.•A remote flowtube for sizes of 500 mm or larger can becombined with the <strong>AXF</strong>A11 Converter only.• Maximum Cable Length:Combination of <strong>AXF</strong> remote Flowtube and <strong>AXF</strong>A11:up to 200 m (660 ft)Combination of <strong>AXF</strong> remote Flowtube and <strong>AXF</strong>A14:up to 100 m (330 ft)10■ HAZARDOUS AREA CLASSIFICATIONFM:*<strong>AXF</strong>002C – <strong>AXF</strong>400CApplicable Standard:FM3600, FM3610, FM3615,FM3810, ANSI/NEMA 250(Integral Flowmeter)Explosion proof for Class I, Division 1, Groups A, B, C& D.Dust-ignition proof for Class II/III, Division1, Groups E,F & G.Intrinsically safe (electrodes) for Class I, Division 1,Groups A, B, C & D.“SEAL ALL CONDUITS WITHIN 18 INCHES”“WHEN INSTALLED IN DIV. 2, SEALS NOT REQUIRED”Electrode Circuit Um: 250 Vac/dcMaximum power supply voltage: 250 Vac/130 VdcExcitation Circuit: 140V maxEnclosure: NEMA 4XTemperature Code: T6Refer to following table;TemperatureCodeT6T5T4T3Maximum ProcessTemperature+70°C (+158°F)+85°C (+185°F)+120°C (+248°F)+130°C (+266°F)Minimum ProcessTemperature–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)Ambient Temp.: –40°C to +60°C (–40°F to +140°F)T27-1_1.EPS(Remote Flowtube)Explosion proof for Class I, Division 1, Groups A, B, C& D.Dust-ignition proof for Class II/III, Division1, Groups E,F & G.Intrinsically safe (electrodes) for Class I, Division 1,Groups A, B, C & D.“SEAL ALL CONDUITS WITHIN 18 INCHES”“WHEN INSTALLED IN DIV. 2, SEALS NOT REQUIRED”Electrode Circuit Um: 250 Vac/dcExcitation Circuit: 170V maxEnclosure: NEMA 4XTemperature Code: T6Refer to following table;TemperatureCodeT6T5T4T3Maximum ProcessTemperature+70°C (+158°F)+85°C (+185°F)+120°C (+248°F)+150°C (+302°F)Minimum ProcessTemperature–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)Ambient Temp.: –40°C to +60°C (–40°F to +140°F)Note: Installation shall be in accordance with themanufacturer’s instructions and National Electriccode, ANSI/NFPA-70.T28-1_1.EPSAll Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00
CENELEC ATEX (KEMA):*<strong>AXF</strong>002C – <strong>AXF</strong>400CApplicable Standard:EN 50014, EN 50018, EN 50019,EN 50020, EN 50028, EN 50281-1-1,EN 60529, EN 61010-1Certificate: KEMA 03ATEX2435(Integral Flowmeter)CENELEC ATEX (KEMA) Flameproof TypeGroup: IICategory: 2GEEx dme[ia] IIC T6...T3Electrode Circuit Um: 250 Vac/dcMaximum power supply voltage: 250 Vac/130 VdcExcitation Circuit: 140V maxEnclosure: IP66, IP67Temperature Class:TemperatureClassT6T5T4T3Maximum ProcessTemperature+70°C (+158°F)+85°C (+185°F)+120°C (+248°F)+130°C (+266°F)Minimum ProcessTemperature–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)Ambient Temp.: –40°C to +60°C (–40°F to +140°F)T27-2.EPSCENELEC ATEX (KEMA) Type of Protection “Dust”Group: IICategory: 1DElectrode Circuit Um: 250 Vac/dcMaximum power supply voltage: 250 Vac/130 VdcExcitation Circuit: 140V maxEnclosure: IP66, IP67Maximum surface temperature:(Remote Flowtube)CENELEC ATEX (KEMA) Flameproof TypeGroup: IICategory: 2GEEx dme[ia] IIC T6...T3Electrode Circuit Um: 250 Vac/dcExcitation Circuit: 170V maxEnclosure: IP66, IP67Temperature Class:TemperatureClassT6T5T4T3Maximum ProcessTemperature+70°C (+158°F)+85°C (+185°F)+120°C (+248°F)+150°C (+302°F)Minimum ProcessTemperature–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)Ambient Temp.: –40°C to +60°C (–40°F to +140°F)11T28-2.EPSCENELEC ATEX (KEMA) Type of Protection “Dust”Group: IICategory: 1DElectrode Circuit Um: 250 Vac/dcExcitation Circuit: 170V maxEnclosure: IP66, IP67Maximum surface temperature:Maximum SurfaceTemperatureT75°C (+167°F)T85°C (+185°F)T100°C (+212°F)T115°C (+239°F)Maximum ProcessTemperature+70°C (+158°F)+85°C (+185°F)+120°C (+248°F)+150°C (+302°F)T30.EPSAmbient Temp.: –40°C to +60°C (–40°F to +140°F)Maximum SurfaceTemperatureT75°C (+167°F)T85°C (+185°F)T100°C (+212°F)Maximum ProcessTemperature+70°C (+158°F)+85°C (+185°F)+120°C (+248°F)T110°C (+230°F) +130°C (+266°F)T29.EPSAmbient Temp.: –40°C to +60°C (–40°F to +140°F)All Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00
- Page 1 and 2: GeneralSpecificationsGS 01E20D01-01
- Page 3 and 4: Functions “”How to Set Paramete
- Page 5 and 6: 5Size of AXF Flowtubes: AXF Standar
- Page 7 and 8: Flowtube Material:Size 2.5 mm (0.1
- Page 9: 9Gasket:Joints:UseLiningGeneral-Pur
- Page 13 and 14: IECEx:*AXF002C - AXF400CApplicable
- Page 15 and 16: Polyurethane Rubber /Natural Soft R
- Page 17 and 18: ■ NORMAL OPERATING CONDITIONSAmbi
- Page 19 and 20: Fluid Temperature and Pressure:Note
- Page 21 and 22: Reasonable Figure for Thermal Shock
- Page 23 and 24: Size500 (20)600 (24)700 (28)800 (32
- Page 25 and 26: 25AXF STANDARD (Wafer /Union Joint
- Page 27 and 28: 27AXF STANDARD (Flange Type) Size 5
- Page 29 and 30: 29REPLACEMENT MODEL FOR EARLIER ADM
- Page 31 and 32: 31■ OPTIONAL SPECIFICATIONS FOR F
- Page 33 and 34: 33 Table of Optional Specifications
- Page 35 and 36: 35 Table of Optional Specifications
- Page 37 and 38: 37■ EXTERNAL DIMENSIONS AXF Stand
- Page 39 and 40: 39 AXF Standard, AXF015, Wafer Type
- Page 41 and 42: 41 AXF Standard, AXF002-AXF015, JIS
- Page 43 and 44: 43 AXF Standard, AXF065-AXF125, JIS
- Page 45 and 46: 45 AXF Standard, AXF250-AXF400, JIS
- Page 47 and 48: 47 AXF Standard, AXF015-AXF125, San
- Page 49 and 50: 49 Replacement model for Earlier AD
- Page 51 and 52: 51 Replacement model for Earlier AD
- Page 53 and 54: 53 AXF Standard, AXF11L-AXF13L, JIS
- Page 55 and 56: 55 Unless otherwise specified, diff