11.07.2015 Views

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CSA:*<strong>AXF</strong>002C – <strong>AXF</strong>400CApplicable Standard:For CSA C22.2 Series;C22.2 No 0, C22.2 No 0.4, C22.2 No 0.5,C22.2 No 25, C22.2 No 30, C22.2 No 94,C22.2 No 157, C22.2 No 1010.1For CSA E79 Series;CAN/CSA-E79-0, CAN/CSA-E79-1,CAN/CSA-E79-7, CAN/CSA-E79-11,CAN/CSA-E79-18Certificate: 1481213(Integral Flowmeter)For CSA C22. 2 SeriesExplosion proof for Class I, Division 1, Groups A, B, C& D.Dust-ignition proof for Class II/III, Division 1, Groups E,F & G.Intrinsically safe (electrodes) for Class I, Division 1,Groups A, B, C & D.“SEAL ALL CONDUITS WITHIN 50 cm OF THEENCLOSURE”“WHEN INSTALLED IN DIV. 2, SEALS NOT REQUIRED”Electrode Circuit Um: 250 Vac/dcMaximum power supply voltage: 250 Vac/130 VdcExcitation Circuit: 140V maxEnclosure: Type 4XTemperature Code:TemperatureCodeT6T5T4T3Maximum ProcessTemperature+70°C (+158°F)+85°C (+185°F)+120°C (+248°F)+130°C (+266°F)Minimum ProcessTemperature–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)Ambient Temp.: –40°C to +60°C (–40°F to +140°F)For CSA E79 SeriesFlameproof for Zone 1, Ex dme[ia] IIC T6...T3Intrinsically safe (electrodes), Ex ia IIC T6...T3Electrode Circuit Um: 250 Vac/dcMaximum power supply voltage: 250 Vac/130 VdcExcitation Circuit: 140V maxEnclosure: IP66, IP67Temperature Code:T27-1.EPS12(Remote Flowtube)For CSA C22.2 SeriesExplosion proof for Class I, Division 1, Groups A, B, C& D.Dust-ignition proof for Class II/III, Division 1, Groups E,F & G.Intrinsically safe (electrodes) for Class I, Division 1,Groups A, B, C & D.“SEAL ALL CONDUITS WITHIN 50 cm OF THEENCLOSURE”“WHEN INSTALLED IN DIV. 2, SEALS NOT REQUIRED”Electrode Circuit Um: 250 Vac/dcExcitation Circuit: 170V maxEnclosure: Type 4XTemperature Code:TemperatureCodeT6T5T4T3Maximum ProcessTemperature+70°C (+158°F)+85°C (+185°F)+120°C (+248°F)+150°C (+302°F)Minimum ProcessTemperature–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)Ambient Temp.: –40°C to +60°C (–40°F to +140°F)For CSA E79 SeriesFlameproof for Zone 1, Ex dme[ia] IIC T6...T3Intrinsically safe (electrodes), Ex ia IIC T6...T3Electrode Circuit Um: 250 Vac/dcExcitation Circuit: 170V maxEnclosure: IP66, IP67Temperature Code:TemperatureCodeT6T5T4T3Maximum ProcessTemperature+70°C (+158°F)+85°C (+185°F)+120°C (+248°F)+150°C (+302°F)–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)–40°C (–40°F)T28-1.EPSMinimum ProcessTemperatureT28-1.EPSAmbient Temp.: –40°C to +60°C (–40°F to +140°F)TemperatureCodeMaximum ProcessTemperatureMinimum ProcessTemperatureT6T5+70°C (+158°F)+85°C (+185°F)–40°C (–40°F)–40°C (–40°F)T4 +120°C (+248°F) –40°C (–40°F)T3 +130°C (+266°F) –40°C (–40°F)Ambient Temp.: –40°C to +60°C (–40°F to +140°F)T27-1.EPSAll Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!