Fluid Temperature and Pressure:Note *1 The following figures show maximum allowablefluid pressure for the flowtube itself. Further fluidpressure should also be limitted according toflange rating.*2 For fluid temperature of the explosion prooftype, refer to descriptions of “HAZARDOUSAREA CLASSIFICATION”.PFA Lining (*1)General-Purpose Use, Submersible Type, Explosionproof Type, Remote Flowtube (electrode structurecode 1: Non-replaceable electrode)PressureMPa (psi)4 (580)2 (290)1 (145)– 0.1 (–14.5)– 40(–40)2.5 to 50 mm (0.1 to 2.0 in.) (flange type, wafer type)65 to 200 mm (2.5 to 8.0 in.) (flange type, wafer type)250, 300 mm (10, 12 in.) (flange type)250, 300 mm (10, 12 in.) (wafer type)350, 400 mm (14, 16 in.) (flange type)*1–10 0 +40+100 +130 +150 +160(+14) (+32) (+104)(+212) (+266) (+302) (+320)Temperature °C (°F)F18-1.EPSGeneral-Purpose Use and Explosion proof Type,Integral Flowmeter (electrode structure code 1:Non-replaceable electrode)PressureMPa (psi)4 (580)2 (290)1 (145)2.5 to 50 mm (0.1 to 2.0 in.) (flange type, wafer type)65 to 200 mm (2.5 to 8.0 in.) (flange type, wafer type)250, 300 mm (10, 12 in.) (flange type)250, 300 mm (10, 12 in.) (wafer type)350, 400 mm (14, 16 in.) (flange type)*1– 0.1 (–14.5)– 40 –10 0 40 100 130(– 40) (14) (32) (104) (212) (266)Temperature °C (°F)F18-2.EPS*1: For lay length code 2 in wafer types of 25 mm (1.0 in.),and for wafer types of 32 mm to 300 mm(1.25 to 12in.), and for carbon steel flange types (process connectioncode: C **) of 50 to 400 mm (2.0 to 16 in.) theminimum temperature is –10°C (+14°F).*2: For fluid temperature of the explosion proof type,refer to descriptions of “HAZARDOUS AREACLASSIFICATION”.19General-Purpose Use, Remote Flowtube (electrodestructure code 2: replaceable electrode)PressureMPa (psi)2 (290)1 (145)– 0.1 (–14.5)25 to 200 mm (1.0 to 8.0 in.) (flange type, wafer type)250, 300 mm (10, 12 in.) (flange type)350, 400 mm (14 to 16 in.) (flange type)250, 300 mm (10, 12 in.) (wafer type)–10 0 40 100(14) (32) (104) (212)Temperature °C (°F)130(266)160(320)F18-3.EPSGeneral-Purpose Use, Integral Flowmeter (electrodestructure code 2: replaceable electrode)PressureMPa (psi)2 (290)1 (145)– 0.1 (–14.5)–10 0(14) (32)25 to 200 mm (1.0 to 8.0 in.) (flange type, wafer type)250, 300 mm (10, 12 in.) (flange type)350, 400 mm (14 to 16 in.) (flange type)250, 300 mm (10, 12 in.) (wafer type)40(104)100(212)130(266)Temperature °C (°F)F18-4.EPSNote: For replaceable electrodes for fluid temperatures of10°C (50°F)or less, please contact Yokogawa office.Sanitary Type (electrode structure code 1: Nonreplaceableelectrode)PressureMPa (psi)1(145)–0.1(–14.5)15 to 125 mm (0.5 to 5.0 in.) (remote flowtube)15 to 125 mm (0.5 to 5.0 in.) (integral <strong>flowmeter</strong>)–10 0(+14) (+32)+130(+266)+160(+320)Temperature °C (°F)Note: In case of 120 to 160°C (248 to 320°F) of fluidtemperature, please select optional code GH.F18-5.EPSCeramics LiningGeneral-Purpose Use and Explosion proof Type,Remote Flowtube (electrode structure code 1: Nonreplaceableelectrode)PressureMPa (psi)4 (580)2.5 to 50 mm (0.1 to 2.0 in.)80 to 200 mm (3.0 to 8.0 in.)2 (290)–0.1 (–14.5)–10 0(+14) (+32)+80 +120(+175) (+248)Temperature °C (°F)+180(+356)F19-1.EPSAll Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!