11.07.2015 Views

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

AXF magnetic flowmeter - Istec Corp.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

51 Replacement model for Earlier ADMAG or ADMAG AE, <strong>AXF</strong>150-<strong>AXF</strong>250, JIS/ANSI/DIN Flange Type,PFA /Polyurethane Rubber Lining<strong>AXF</strong>150 G<strong>AXF</strong>200 W<strong>AXF</strong>250 C*4DEFNP12NAU12C AC DC JC G 12*4: D, E, F; Integral Flowmeter,N, P; Remote FlowtubeUnit : mm (approx. inch)Integral Flowmeter Remote Flowtube Integral Flowmeter Remote FlowtubeGround Terminal(M4)197(7.76)* 1 N- øh49 (1.93)73(2.87)154(6.06)70(2.76)Ground Terminalø86 (3.38) (M4)48(1.89)Eye Bolt66* 1 51.5 51.5(2.6) (2.03) (2.03)28(1.1)ø128(5.04)111(4.37)øDHiH1(H2)H3HrøC(ød)* No infra-red switches are furnishedfor Fieldbus communication type.L* 2t * 2θ°ModelRemoteflowtubePitch circle dia. øCIntegral<strong>flowmeter</strong> Bolt hole interval ˚Hole dia. øhNumber of holes NHeight H1Height H2Height H3Max. Height HrRemoteflowtubeIntegral<strong>flowmeter</strong>Process ConnectionSize codeSizeLining codeFace-to-facelengthOutside dia.ThicknessInner diameter ofGrounding ringWeight kg (lb)*3Max. HeightWeight kg (lb)L*2øDt *2ødHi150150(6)A,U270(10.63)280(11.02)31(1.22)140.7(5.54)240(9.45)22.523(0.91)8284(11.18)141(5.55)325(12.80)408(16.06)29(63.9)446(17.56)30.7(67.7)CJ1(JIS10K) CJ2(JIS20K) CG1(JIS F12) CA1(ANSI Class 150) CA2(ANSI Class 300) CD1(DIN PN10) CD2(DIN PN16)200200(8)A,U340(13.39)330(12.99)31(1.22)188.9(7.44)290(11.42)1523(0.91)12334(13.15)166(6.54)375(14.76)458(18.03)39(86.0)496(19.53)40.7(89.7)*1: When indicator code N is selected, subtract 12 mm (0.47 inch) from the value in the figure.In case of explosion proof type with indicator, add 5 mm (0.2 inch) to it.*2: Depending on the selection of grounding ring code and optional code, add the following value to “L” (face-to-face length) and “t” (thickness offlange).Nominal Size: 150, 200 mmL t L t L tGrounding Ring Code S, L, H, V P, T NNone +0 +0 +28(1.1) +14(0.55) -6(0.24) -3(0.12)OptionCode GA, GC, GD +2(0.08) +1(0.04) +30(1.81) +15(0.59) – –(Special Gaskets)250250(10)A,U430(16.93)400(15.75)33(1.30)243(9.57)355(13.98)1525(0.98)12400(15.75)197(7.76)454(17.87)524(20.63)64(141.1)562(22.13)65.7(144.8)150150(6)A,U270(10.63)305(12.01)37(1.46)140.7(5.54)260(10.24)1525(0.98)12297(11.69)141(5.55)350(13.78)421(16.57)38.3(84.4)459(18.07)40.0(88.2)200200(8)A,U340(13.39)350(13.78)39(1.54)188.9(7.44)305(12.01)1525(0.98)12344(13.54)166(6.54)395(15.55)468(18.43)53.6(118.2)506(19.92)55.3(121.9)250250(10)A,U430(16.93)430(16.93)43(1.69)243(9.57)380(14.96)1527(1.06)12415(16.34)197(7.76)484(19.06)539(21.22)92.5(203.9)577(22.72)94.2(207.7)150150(6)A,U270(10.63)290(11.42)31(1.22)145.4(5.72)247(9.72)3019(0.75)6289(11.38)141(5.55)335(13.19)413(16.26)31.1(68.6)451(17.76)32.8(72.3)200200(8)A,U340(13.39)342(13.46)33(1.30)192.9(7.59)299(11.77)22.519(0.75)8340(13.39)166(6.54)387(15.24)464(18.27)44.6(98.3)502(19.76)46.3(102.1)250250(10)A,U430(16.93)410(16.14)33(1.30)243(9.57)360(14.17)22.523(0.91)8405(15.94)197(7.76)464(18.27)529(20.83)67.4(148.6)567(22.32)69.1(152.3)150150(6)A,U270(10.63)279.4(11.00)34.4(1.35)140.7(5.54)241.3(9.50)22.522.4(0.88)Nominal Size: 250 mmL t L tGrounding Ring Code S, L, H, V NOption Code is “None”8284(11.18)141(5.55)324(12.76)408(16.06)32.1(70.7)446(17.56)33.8(74.4)200200(8)A,U340(13.39)342.9(13.50)37.4(1.47)188.9(7.44)298.5(11.75)22.522.4(0.88)8340(13.39)166(6.54)387(15.24)464(18.27)50.9(112.2)502(19.76)52.6(115.9)250250(10)A,U430(16.93)406.4(16.00)39.2(1.54)243(9.57)362.0(14.25)1525.4(1.00)12403(15.87)197(7.76)460(18.11)527(20.75)77.4(170.6)565(22.24)79.1(174.4)150150(6)A,U270(10.63)317.5(12.50)47.5(1.87)140.7(5.54)269.7(10.62)1522.4(0.88)12303(11.93)141(5.55)362(14.25)427(16.81)53.7(118.4)465(18.31)55.4200200(8)A,U340(13.39)381.0(15.00)50.1(1.97)188.9(7.44)330.2(13.00)1525.4(1.00)12360(14.17)166(6.54)426(16.77)484(19.06)80.5(177.5)522(20.55)82.2(122.1) (181.2)+0 +0 -6(0.24) -3(0.12)250250(10)A,U430(16.93)444.5(17.50)56.7(2.23)243(9.57)387.4(15.25)11.2528.4(1.12)16422(16.61)197(7.76)499(19.65)546(21.50)127.0(279.9)584(22.99)128.7(283.6)200200(8)A,U340(13.39)340(13.39)33(1.30)188.9(7.44)295(11.61)22.522(0.87)8339(13.35)166(6.54)385(15.16)463(18.23)44.2(97.5)501(19.72)45.9(101.2)250250(10)A,U430(16.93)395(15.55)35(1.38)243(9.57)350(13.78)1522(0.87)12397(15.63)197(7.76)449(17.68)521(20.51)67.0(147.7)559(22.01)68.7(151.5)150150(6)A,U270(10.63)285(11.22)31(1.22)140.7(5.54)240(9.45)22.522(0.87)8287(11.30)141(5.55)330(12.99)411(16.18)29.9(65.8)449(17.68)31.6(69.6)200200(8)A,U340(13.39)340(13.39)33(1.30)188.9(7.44)295(11.61)1522(0.87)12339(13.35)166(6.54)385(15.16)463(18.23)43.6(96.2)501(19.72)45.3(100.0)250250(10)A,U430(16.93)405(15.94)35(1.38)243(9.57)355(13.98)1526(1.02)12402(15.83)197(7.76)459(18.07)526(20.71)68.8(151.7)564(22.20)70.5(155.5)*3: When submersible type or option code DHC is selected, waterproof glands and a 30m long cable are attached.Add 9.5kg(20.9lb) to the weight in the table.F40.EPSAll Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!