48 <strong>AXF</strong> Standard, <strong>AXF</strong>015-<strong>AXF</strong>125, Sanitary for Butt Weld, PFA LiningUnit : mm (approx. inch)Integral FlowmeterRemote FlowtubeIntegral FlowmeterRemote Flowtube<strong>AXF</strong>015<strong>AXF</strong>025<strong>AXF</strong>032<strong>AXF</strong>040<strong>AXF</strong>050 H<strong>AXF</strong>065<strong>AXF</strong>080<strong>AXF</strong>100<strong>AXF</strong>125*3DE 1F 2N NPA L 1 NK KK D*3: D, E, F; Integral Flowmeter,N, P; Remote FlowtubeBB 1Hi73(2.87) 49(1.93)154(6.06)Ground Terminal(M4)ø86(3.38)Hr70(2.76)H148(1.89)Ground Terminal(M4)197(7.76)*166*1 51.5 51.5(2.6) (2.03) (2.03)28(1.1)ø128(5.04)Adapter for butt weld connection111(4.37)øD(ød)ModelProcess ConnectionSize codeHeightSizeLining codeFace-to-facelengthLOutside dia. øDRemoteFlowtubeKKBInner dia. ødIntegralKDBFlowmeterRemoteFlowtubeIntegralFlowmeterMax. HeightMax. HeightH1Hr* 2Weight kg (lb)HiWeight kg (lb)01515(0.5)A126(4.98)73(2.87)15.2(0.60)16(0.63)98(3.86)222(8.74)2.6(5.7)260(10.24)4.3(9.5)02525(1)A126(4.98)73(2.87)22.6(0.89)26(1.02)98(3.86)222(8.74)2.3(5.1)260(10.24)4(8.8)03232(1.3)A126(4.98)73(2.87)31.3(1.23)32(1.26)98(3.86)222(8.74)2.5(5.5)260(10.24)4.2(9.3)* No infra-red switches are furnishedfor Fieldbus communication type.KKB / KDB04040(1.5)A126(4.98)86(3.39)35.6(1.40)38(1.50)111(4.37)235(9.25)2.8(6.2)273(10.73)4.5(9.9)05050(2)A136(5.37)99(3.90)48.6(1.91)50(1.97)129(5.08)253(9.96)3.4(7.5)291(11.44)5.1(11.2)06565(2.6)A156(6.16)117(4.61)60.3(2.37)66(2.60)147(5.79)271(10.67)4.5(9.9)309(12.17)6.2(13.7)08080(3)A176(6.94)129(5.08)72.9(2.87)81(3.19)157(6.18)281(11.06)5.3(11.7)319(12.54)7(15.4)100100(4)A206(8.13)155(6.10)97.6(3.84)100(3.94)183(7.20)307(12.09)7.1(15.7)345(13.56)8.8(19.4)125125(5)A276(10.88)183(7.20)135.7(5.34)125(4.92)212(8.35)336(13.23)11(24.3)374(14.70)12.7(28.0)L*1: When indicator code N is selected, subtract 12 mm(0.47 inch) from the value in the figure.*2: When option code DHC is selected, waterproofglands and a 30m long cable are attached.Add 9.5kg (20.9lb) to the weight in the table.øAøBEødøCAdapter for butt weld connectionProcessConnectionNominalSizeøAøBøCødEParts No.1570(2.76)16(0.63)18(0.71)15.2(0.60)30(1.18)F9811NN2570(2.76)22.2(0.87)25.6(1.01)22.6(0.89)30(1.18)F9811NP3270(2.76)29.4(1.16)34.3(1.35)31.3(1.23)30(1.18)F9811NQKKB (ISO2037 Butt Weld)4083(3.27)34.6(1.36)38.6(1.52)35.6(1.40)30(1.18)F9811NR5096(3.78)47.6(1.87)51.6(2.03)48.6(1.91)30(1.18)F9811NS65114(4.49)59.5(2.34)64.1(2.52)60.3(2.37)30(1.18)F9811NT80126(4.96)72.3(2.85)76.7(3.02)72.9(2.87)30(1.18)F9811NU100152(5.98)97(3.82)102.5(4.04)97.6(3.84)30(1.18)F9811NV125180(7.09)123(4.84)141.2(5.56)135.7(5.34)40(1.57)F9811NW1570(2.76)16(0.63)20(0.79)16(0.63)30(1.18)F9811ND2570(2.76)22.2(0.87)30(1.18)26(1.02)30(1.18)F9811NE3270(2.76)29.4(1.16)36(1.42)32(1.26)30(1.18)F9811NFKDB (DIN 1185 Butt Weld)4083(3.27)34.6(1.36)42(1.65)38(1.50)30(1.18)F9811NG5096(3.78)47.6(1.87)54(2.13)50(1.97)30(1.18)F9811NH65114(4.49)59.5(2.34)70(2.76)66(2.60)30(1.18)F9811NJ80126(4.96)72.3(2.85)85(3.35)81(3.19)30(1.18)F9811NK100152(5.98)97(3.82)104(4.09)100(3.94)30(1.18)F9811NL125180(7.09)123(4.84)129(5.08)125(4.92)40(1.57)F9811NMF36.EPSAll Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>orationGS 01E20D01-01E May 10,2006-00
49 Replacement model for Earlier ADMAG or ADMAG AE, <strong>AXF</strong>002-<strong>AXF</strong>015, Wafer Type, PFA Lining<strong>AXF</strong>002G<strong>AXF</strong>005W<strong>AXF</strong>010C<strong>AXF</strong>015*4DEF12 A 1 A 2N NP*4: D, E, F; Integral Flowmeter,N, P; Remote Flowtube49(1.93)Hi73(2.87)Unit : mm (approx. inch)Integral Flowmeter Remote Flowtube Integral Flowmeter Remote Flowtube197(7.76)* Ground TerminalGround Terminal(M4)154(6.06)(M4)66* 1 51.5 51.5 28(1.1)ø86(3.38) (2.6) (2.03) (2.03)48 (1.89)111(4.37)Hr70(2.76)H163.5(2.50)3(0.12)Dø128(5.04)(ød)* No infra-red switches are furnishedfor Fieldbus communication type.L* 24- ø6.2(0.24)7258(2.83)(2.28)Size codeModel SizeLining codeFace-to-faceRemotelength L *2Flowtube Outside dia. DIntegralFlowmeterRemoteFlowtubeInner diameter ofGrounding ringHeightMax. HeightødWeight kg (lb)H1Hr* 30022.5(0.1)A005 0105(0.2) 10(0.4)A A85(3.35)44(1.73)15(0.59)144(5.67)265(10.43)2.4(5.3)01515(0.5)A*1: When indicator code N is selected, subtract 12 mm (0.47 inch)from the value in the figure.In case of explosion proof type with indicator, add 5 mm (0.2inch) to it.*2: Depending on the selection of grounding ring code and optionalcode, add the following value to L (face-to-face length).Grounding Ring Code S, L, H, V P, T NOptionCodeNoneGA, GC, GD(Special Gaskets)+0 +22(0.87) -6(0.24)+2(0.08) +24(0.94) –*3: When submersible type or option code DHC is selected,waterproof glands and a 30m long cable are attached.Add 9.5kg(20.9lb) to the weight in the table.Max. Height HiIntegralFlowmeterWeight kg (lb)306(12.03)4.1(9.0)F37.EPS Replacement model for Earlier ADMAG or ADMAG AE, <strong>AXF</strong>025-<strong>AXF</strong>100, Wafer Type,PFA /Polyurethane Rubber LiningUnit : mm (approx. inch)Integral Flowmeter Remote Flowtube Integral Flowmeter Remote Flowtube<strong>AXF</strong>025<strong>AXF</strong>040 G<strong>AXF</strong>050 W<strong>AXF</strong>080 C<strong>AXF</strong>100*4DE 1AF 2UN NP1 A 2*4: D, E, F; Integral Flowmeter,N, P; Remote Flowtube49(1.93)Hi73(2.87)154(6.06)Ground Terminal(M4)ø86(3.38)Hr70(2.76)H148(1.89)197(7.76)*166*1 51.5 51.5(2.6) (2.03) (2.03)Ground Terminal(M4)28(1.1)111(4.37)ø128(5.04)øD(ød)ModelSize codeSizeLining code02525(1)A,U04040(1.5)A,UFace-to-facelengthRemoteFlowtube Outside dia.L *2øD93(3.66) 106(4.17)67.5(2.66) 86(3.39) 99(3.90) 129(5.08) 155(6.10)IntegralFlowmeterInner diameter ofGrounding ring ød 27(1.06) 40(1.57) 52(2.05) 81(3.19) 98(3.86)HeightRemoteMax. HeightH1Hr92(3.62) 111(4.37) 129(5.08) 157(6.18) 183(7.20)216(8.50) 235(9.25) 253(9.96) 281(11.06) 307(12.09)FlowtubeWeight kg (lb)* 3 3.1(6.7) 3.5(7.7) 4.2(9.3) 6.4(14.1) 8.0(17.6)* No infra-red switches are furnishedL*2for Fieldbus communication type.050 080 100*1: When indicator code N is selected, subtract 12 mm (0.47 inch)from the value in the figure.50(2) 80(3) 100(4)In case of explosion proof type with indicator, add 5 mm (0.2inch) to it.A,U A,U A,U*2: Depending on the selection of grounding ring code and optionalGrounding Ring Code S, L, H, V P, T N120(4.72) 160(6.30) 180(7.09)OptionCodeNoneGA, GC, GD(Special Gaskets)+0 +22(0.87) -6(0.24)+2(0.08) +24(0.94) –*3: When submersible type or option code DHC is selected,waterproof glands and a 30m long cable are attached.Add 9.5kg(20.9lb) to the weight in the table.Max. Height HiIntegralFlowmeterWeight kg (lb)254(9.98) 273(10.73) 291(11.44) 319(12.54) 345(13.56)4.8(10.5) 5.2(11.4) 5.9(13.1) 8.1(17.9) 9.7(21.3)F38.EPSAll Rights Reserved. Copyright © 2003, Yokogawa Electric <strong>Corp</strong>oration GS 01E20D01-01E May 10,2006-00
- Page 1 and 2: GeneralSpecificationsGS 01E20D01-01
- Page 3 and 4: Functions “”How to Set Paramete
- Page 5 and 6: 5Size of AXF Flowtubes: AXF Standar
- Page 7 and 8: Flowtube Material:Size 2.5 mm (0.1
- Page 9 and 10: 9Gasket:Joints:UseLiningGeneral-Pur
- Page 11 and 12: CENELEC ATEX (KEMA):*AXF002C - AXF4
- Page 13 and 14: IECEx:*AXF002C - AXF400CApplicable
- Page 15 and 16: Polyurethane Rubber /Natural Soft R
- Page 17 and 18: ■ NORMAL OPERATING CONDITIONSAmbi
- Page 19 and 20: Fluid Temperature and Pressure:Note
- Page 21 and 22: Reasonable Figure for Thermal Shock
- Page 23 and 24: Size500 (20)600 (24)700 (28)800 (32
- Page 25 and 26: 25AXF STANDARD (Wafer /Union Joint
- Page 27 and 28: 27AXF STANDARD (Flange Type) Size 5
- Page 29 and 30: 29REPLACEMENT MODEL FOR EARLIER ADM
- Page 31 and 32: 31■ OPTIONAL SPECIFICATIONS FOR F
- Page 33 and 34: 33 Table of Optional Specifications
- Page 35 and 36: 35 Table of Optional Specifications
- Page 37 and 38: 37■ EXTERNAL DIMENSIONS AXF Stand
- Page 39 and 40: 39 AXF Standard, AXF015, Wafer Type
- Page 41 and 42: 41 AXF Standard, AXF002-AXF015, JIS
- Page 43 and 44: 43 AXF Standard, AXF065-AXF125, JIS
- Page 45 and 46: 45 AXF Standard, AXF250-AXF400, JIS
- Page 47: 47 AXF Standard, AXF015-AXF125, San
- Page 51 and 52: 51 Replacement model for Earlier AD
- Page 53 and 54: 53 AXF Standard, AXF11L-AXF13L, JIS
- Page 55 and 56: 55 Unless otherwise specified, diff