<strong>StreamPro</strong> <strong>ADCP</strong> <strong>Operation</strong> <strong>Manual</strong>PT - Built-In TestsPurposeFormatRangeSends/displays results of <strong>ADCP</strong> system diagnostic test.PTnnnnnn = 0 to 200 (PT0 = Help menu)Recommended Setting. Use as needed.DescriptionThese diagnostic tests check the major <strong>ADCP</strong> modules andsignal paths.PT0 - HelpDisplays the test menu (shown below). As implied by the NOTE, adding100 to the test number repeats the test continually until the <strong>ADCP</strong> receives a= = =. Sending PT200 runs all tests. PT300 runs all tests continually untilthe <strong>ADCP</strong> receives a = = =.>pt0Built In Tests----------------PT0 = HelpPT1 = NAPT2 = Show SensorsPT3 = Receive Path TestPT10n = auto (n) test repeatPT200 = auto cycle All testsPT2 – Show SensorsThis test displays the values for ambient temperature sensor. This sensor isimbedded in the transducer head, and is used for water temperature reading.>pt203/03/03 20:07:57.05 23.1875 CP/N 95B-6003-00 (February 2008) page 51