11.07.2015 Views

StreamPro ADCP Operation Manual - global site

StreamPro ADCP Operation Manual - global site

StreamPro ADCP Operation Manual - global site

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>StreamPro</strong> <strong>ADCP</strong> <strong>Operation</strong> <strong>Manual</strong>Table 11:Hex DigitBinaryByteVariable Leader Data Format (continued)Field33-36 17,18 ED / Depth ofTransducerDescriptionContains the depth of the transducer below the water surface(ED-command). This value may be a manual setting or areading from a depth sensor.Scaling: LSD = 1 decimeter; Range = 1 to 9999 decimeters37-40 19,20 EH / Heading Contains the <strong>StreamPro</strong> heading angle (EH-command). Thisvalue may be a manual setting or a reading from a headingsensor.Scaling: LSD = 0.01 degree; Range = 000.00 to 359.99 degrees41-44 21,22 EP / Pitch (Tilt 1) Contains the <strong>StreamPro</strong> pitch angle (EP-command). Thisvalue may be a manual setting or a reading from a tilt sensor.Positive values mean that Beam #3 is spatially higher thanBeam #4.Scaling: LSD = 0.01 degree; Range = -20.00 to +20.00 degrees45-48 23,24 ER / Roll (Tilt 2) Contains the <strong>StreamPro</strong> roll angle (ER-command). Thisvalue may be a manual setting or a reading from a tilt sensor.For up-facing <strong>StreamPro</strong> <strong>ADCP</strong>s, positive values mean thatBeam #2 is spatially higher than Beam #1. For down-facing<strong>StreamPro</strong> <strong>ADCP</strong>s, positive values mean that Beam #1 isspatially higher than Beam #2.Scaling: LSD = 0.01 degree; Range = -20.00 to +20.00 degrees49-52 25,26 ES / Salinity Contains the salinity value of the water at the transducerhead (ES-command). This value may be a manual setting ora reading from a conductivity sensor.Scaling: LSD = 1 part per thousand; Range = 0 to 40 ppt53-56 27,28 ET / Temperature57,5859,6061,6263,6465,6667,68293031323334MPT minutesMPT secondsMPT hundredthsH/Hdg Std DevP/Pitch Std DevR/Roll Std DevContains the temperature of the water at the transducer head(ET-command). This value may be a manual setting or areading from a temperature sensor.Scaling: LSD = 0.01 degree; Range = -5.00 to +40.00 degreesThis field contains the Minimum Pre-Ping Wait Time betweenping groups in the ensemble.These fields contain the standard deviation (accuracy) of theheading and tilt angles from the gyrocompass/pendulums.Scaling (Heading): LSD = 1°; Range = 0 to 180° Scaling(Tilts): LSD = 0.1°; Range = 0.0 to 20.0°P/N 95B-6003-00 (February 2008) page 69

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!