Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
FC100-CA | Flow MeterInstallationGMBH2.1.7 Condensate depositsOil or water deposits on the sensors may falsify the measuring results. Such deposits must be expected,for example, when high flow velocities of compressed air are concerned and there is no dryingprovided. Normal condensation on an unheated sensor is normally not detected. It will dry after afew minutes. Deposits on heated sensors only occur at high air humidities and will cause significantmeasuring errors. In most cases, such deposits will dry within a few minutes.Deposits of oil, however, will not dry and should be removed at regular intervals.2.1.8 Electrical connectionCable Do + Ka type xx(depends on FC100-CA version)21greenyellowgreen 7 7yellow 3 3R(HEIZ)65redblueredpink4 48 8R(Tdiff)109347/8pinkgreybrownwhiteblackshieldgreybrownwhiteblue1 15 56 62 2R(HEIZ)R(Tref)XSKFC100-CAcableKabel-UnionLifYCY 4 x 2 x 0,2 mm 2or equivalent cablecircular plugX221 368 01flange plugX221 369 01monitoring headfig. 1423