11.07.2015 Views

User ManUal - FlowVision GmbH

User ManUal - FlowVision GmbH

User ManUal - FlowVision GmbH

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GMBHFlow Meter | FC100-CATechnical Data7.5.1.2 Monitoring heads CST and CSF-…Flow measurement ranges:The flow measurement range is determined by the inside pipe diameter (see table).It can be calculated with the following equation:Setting range for inside pipe diameter:Velocity range:Q = V N x A RQ [Nm 3 /h] - flow quantityV N [m/h] - average standard velocityA R [m 2 ] - inside pipe cross-section10.0 mm … 999.9 mm0 … 68 Nm/s (100 Nm/s)Accuracy 1) : ± 5 % MW ** / ±0.5 % MBE *Repeatability (5% MBE to 100% MBE):Temperature drift:Inside pipe diameterMeasuring rangeD in mmin Nm 3 /hin Nm 3 /h20 76 11330 173 25440 307 45250 480 70660 692 101770 942 138580 1230 180990 1557 2290100 1922 2827150 4325 6361200 7690 11309250 12016 17671300 17303 25446400 30762 45238500 48066 70685600 69215 101787700 94210 138544800 123049 180955900 155734 2290211000 192265 282743± 1 % MW / ±0.5 % MBE± 0.05 %/K/MBEDisplay range7.5.2 Temperature measurementMeasuring range: - 40 … +130 °C / -40 … +266 °FAccuracy: ±1 % MB ***68

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!