11.07.2015 Views

User ManUal - FlowVision GmbH

User ManUal - FlowVision GmbH

User ManUal - FlowVision GmbH

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GMBHFlow Meter | FC100-CATechnical Data7 Technical data7.1 Ambient conditionsrail-mounted versionsurface mounted versionStorage temperature: -20 … 70 °C -20 … 70 °CAmbient temperature: 5 … 50 °C 5 … 50 °CDegree of protection: IP20 IP657.2 Electrical characteristicsDC supplyConnector pin assignment: signal name Pin XVCaution!Pin XV1 (Shield) is internally connected to pin XV3 (-U v ).The housing is connected to shield potential.shield 1+U V 2-U V 3Input voltage range:U V = DC 10 … 40V (ripple incl.)Admissible ripple:max. 20% U VMax. current consumption:I = 650mA at U V = 10VI = 500mA at U V = 12VI = 240mA at UV = 24VI = 150mA at U V = 40V62

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!