12.07.2015 Views

Altistart 22 - Schneider Electric

Altistart 22 - Schneider Electric

Altistart 22 - Schneider Electric

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SelectionStandard application, <strong>Altistart</strong> <strong>22</strong>•••Q, 230/440 V supply,soft starter inside delta connectionOnly the <strong>Altistart</strong> <strong>22</strong>pppQ can be installed inside delta connection.NOTICERISK OF DAMAGE TO THE MOTORATS<strong>22</strong>pppS6 and ATS<strong>22</strong>pppS6U must not be installed inside delta connection.Failure to follow these instructions can result in equipment damage.Motor Soft starter 230/440 V (+ 10% - 15%) - 50/60 Hz (+/- 10%)Nominal motor power230 V 400 V 440 V(1)Line current is maximum 1.5 IcL. Also, the In setting must not exceed IcL.Example: for a 400 V - 110 kW motor with a line current of 195 A, the minimum soft starter rated current,IcL = 195/1.5 = 130 A.Thus select ATS<strong>22</strong>C14QThe nominal motor current In must not exceed the max. permanent current in class 10.See wiring page 26.Maximum surrounding temperatureLine current(Motor FLA) (1)In setting(Line current/3)Soft starterrated currentIcL(soft starter FLA)Soft starterreferencekW kW kW A A A5.5 11 15 25 14,4 17 ATS<strong>22</strong>D17Q11 <strong>22</strong> <strong>22</strong> 48 27,7 32 ATS<strong>22</strong>D32Q18.5 45 45 70 40,4 47 ATS<strong>22</strong>D47Q<strong>22</strong> 55 55 93 53,7 62 ATS<strong>22</strong>D62Q30 55 75 112 64,7 75 ATS<strong>22</strong>D75Q37 75 75 132 76,2 88 ATS<strong>22</strong>D88Q45 90 90 165 95,3 110 ATS<strong>22</strong>C11Q55 110 110 210 121,2 140 ATS<strong>22</strong>C14Q15 132 132 255 147,2 170 ATS<strong>22</strong>C17Q90 160 160 315 181,9 210 ATS<strong>22</strong>C21Q110 <strong>22</strong>0 <strong>22</strong>0 375 216,5 250 ATS<strong>22</strong>C25Q132 250 250 480 277,1 320 ATS<strong>22</strong>C32Q160 315 355 615 355,1 410 ATS<strong>22</strong>C41Q<strong>22</strong>0 355 400 720 415,7 480 ATS<strong>22</strong>C48Q250 400 500 885 511,0 590 ATS<strong>22</strong>C59QThe information in the table above is based on operation at a maximum ambient temperature of 40°C (104°F) and mini. -10°C (-50°F).The <strong>Altistart</strong> <strong>22</strong> can be used up to an ambient temperature of 60°C (140°F) as long as the max. permanent current in class 10 is deratedby 2.2% for each degree above 40°C (104°F).Example: ATS<strong>22</strong>D32Q at 50°C (1<strong>22</strong>°F) derated by 10 x 2.2% = <strong>22</strong>%, 48 A becomes 48 x 0.78 = 37.5 A (max. nominal motor current).12 BBV51330 08/2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!